Chest Radiography Optimization: Identifying the Optimal kV for Image Quality in a Phantom Study.

Ioannis Antonakos, Kyriakos Kokkinogoulis, Maria Giannopoulou, Efstathios P Efstathopoulos

Abstract read
In one paragraph

Article in Journal of imaging, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Ioannis AntonakosDepartment of Applied Medical Physics, Medical School, National and Kapodistrian University of Athens, 124 62 Athens, Greece.ORCID 0000-0002-3165-9022
Kyriakos KokkinogoulisDepartment of Applied Medical Physics, Medical School, National and Kapodistrian University of Athens, 124 62 Athens, Greece.ORCID 0009-0005-6478-9738
Maria GiannopoulouDepartment of Applied Medical Physics, Medical School, National and Kapodistrian University of Athens, 124 62 Athens, Greece.
Efstathios P EfstathopoulosDepartment of Applied Medical Physics, Medical School, National and Kapodistrian University of Athens, 124 62 Athens, Greece.ORCID 0000-0003-2747-3353

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Chest radiography remains one of the most frequently performed imaging examinations, highlighting the need for optimization of acquisition parameters to balance image quality and radiation dose. This study presents a phantom-based quantitative evaluation of chest radiography acquisition settings using a digital radiography system (AGFA DR 600). Measurements were performed at three tube voltage levels across simulated patient-equivalent thicknesses generated using PMMA slabs, with a Leeds TOR 15FG image quality phantom positioned centrally in the imaging setup. Image quality was quantitatively assessed using signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), which were calculated from mean pixel values obtained from repeated acquisitions. Radiation exposure was evaluated through estimation of entrance surface dose (ESD). The analysis demonstrated that dose-normalized performance metrics favored intermediate tube voltages for slim and average patient-equivalent thicknesses, while higher voltages were required to maintain image quality in obese-equivalent conditions. Overall, image quality and dose were found to be strongly dependent on the combined selection of tube voltage and phantom thickness. These findings indicate that modest adjustments to tube voltage selection may improve the balance between image quality and radiation dose in chest radiography. Nevertheless, as the present work is based on phantom measurements, further validation using clinical images and observer-based studies is required before any modification of routine radiographic practice.

Indexed as

chest radiographycontrast-to-noise ratiodose optimizationentrance surface doseimage qualitysignal-to-noise ratio