Evidence map›Paper›PMID 41590801›Full record

ArticleJournal of functional biomaterials2026

Efficiency and Risk Assessment of Dental Bridge Removal Tools on Implant Abutments.

Gianmario Schierano, Domenico Baldi, Cristina Bignardi, Mara Terzini, Andrea Tancredi Lugas

Abstract read
In one paragraph

Article in Journal of functional biomaterials, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Gianmario SchieranoDepartment of Surgical Sciences, C.I.R. Dental School, University of Turin, Via Nizza 230, 10126 Turin, Italy.ORCID 0000-0003-1271-3334
Domenico BaldiDepartment of Surgical Sciences (DISC), Division of Prosthetic Dentistry, University of Genoa, Largo R. Benzi 10, 16132 Genoa, Italy.ORCID 0000-0002-5408-3345
Cristina BignardiPolitoBIOMed Lab, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Turin, Italy.ORCID 0000-0002-7065-2552
Mara TerziniPolitoBIOMed Lab, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Turin, Italy.ORCID 0000-0002-5699-6009
Andrea Tancredi LugasPolitoBIOMed Lab, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Turin, Italy.ORCID 0000-0002-9660-5551

Funding

University of Turin SCHG_RILO_23_01 RICERCA LOCALE 2023
6 · The paper itself

Abstract

This study evaluated the efficiency and potential risks associated with three clinical tools for removing cement-retained implant-supported prostheses: Magnetic Mallet, sliding hammer, and Coronaflex. The tests consisted of: cementation of three-unit bridge models onto titanium abutments with different geometries using Zinc Oxide non-eugenol or Zinc Phosphate cement. Seven different geometries of three-unit bridges were tested; therefore, a total of 7 bridges × 2 luting agents × 3 tools were combined in a full factorial analysis. Five test replicates were performed for each combination, resulting in a total of 5 × 7 × 2 × 3 = 210 retrieval tests. The 70 tests regarding the Coronaflex were taken from a previously conducted experiment on the topic, using the same dental bridge models and the same experimental conditions. Efficiency was assessed by the percentage of successful removals and the maximum force recorded with a piezoelectric load cell. For temporary cementations, the sliding hammer achieved the highest retrieval rate, while the Magnetic Mallet demonstrated comparable efficiency with lower forces. Coronaflex showed lower success rates and higher forces than Magnetic Mallet. For permanent cementations, most bridges were not removable, and attempts with the sliding hammer occasionally resulted in abutment screw damage. Within the limitations of this study, the Magnetic Mallet appears to be an effective option for removing bridges cemented with temporary cement, potentially in combination with a sliding hammer for highly retentive geometries. Zinc phosphate cement should be avoided when retrievability is desired, except for abutments with very low retention capability.

Indexed as

cementdental implantsefficiencyfixed bridgeprosthesisremoval tools

Identifiers

PMID41590801
PMCPMC12843061

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.