Ring Artifact Reduction in Photon Counting CT Using Redundant Sampling and Autocalibration.
Article in IEEE transactions on medical imaging, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
Ring artifacts in CT are caused by uncalibrated variations in detector pixels and are especially prevalent with emerging photon counting detectors (PCDs). Control of ring artifacts is conventionally accomplished by improving either hardware manufacturing or software correction algorithms. An alternative solution is detector autocalibration, in which two redundant samples of each line integral are acquired and used to dynamically calibrate the PCD. Autocalibration was first proposed by Hounsfield in 1977 and was demonstrated on the EMI Topaz prototype scanner in 1980, but details surrounding this implementation are sparse. We investigate a form of autocalibration that requires just two redundant acquisitions, which could be acquired using flying focal spot on a clinical scanner but is demonstrated here with a detector shift. We formulated autocalibration as an optimization problem to determine the relative gain factor of each pixel and tested it on scans of a chicken thigh specimen, resolution phantom, and a cylindrical phantom. Ring artifacts were significantly reduced. Some residual artifacts remained but could not be discriminated from the intrinsic temporal instability of our PCD modules. Autocalibration could facilitate the adoption of widespread photon counting CT by reducing ring artifacts, thermal management requirements, or stability requirements that are present today. Demonstration of autocalibration on a rotating gantry with flying focal spot remains future work.