ArticleEuropean radiology experimental2026

Phantom-based performance comparison of two commercial deep learning CT reconstruction algorithms with super- and normal-resolution settings.

Joël Greffier, Catherine Roy, Djamel Dabli, Jean-Paul Beregi, Maxime Pastor

Abstract readComparative Study
In one paragraph

Article in European radiology experimental, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Joël GreffierIMAGINE UR UM 103, Montpellier University, Department of Medical Imaging, Nîmes University Hospital, Nîmes, France. joel.greffier@chu-nimes.fr.ORCID http://orcid.org/0000-0002-1735-5129
Catherine RoyDiagnostic Imagery Department, Nouvel Hôpital Civil (NHC), Hôpitaux Universitaires de Strasbourg, Strasbourg, France.
Djamel DabliIMAGINE UR UM 103, Montpellier University, Department of Medical Imaging, Nîmes University Hospital, Nîmes, France. djamel.dabli@chu-nimes.fr.
Jean-Paul BeregiIMAGINE UR UM 103, Montpellier University, Department of Medical Imaging, Nîmes University Hospital, Nîmes, France.
Maxime PastorIMAGINE UR UM 103, Montpellier University, Department of Medical Imaging, Nîmes University Hospital, Nîmes, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveWe compared a super-resolution deep learning image reconstruction (SR-DLR) algorithm with a normal-resolution (NR)-DLR algorithm according to radiation dose for abdominal computed tomography (CT). MATERIALS AND

methodsAn image-quality phantom was scanned with an energy-integrating detectors CT unit at three volume CT dose index radiation dose levels (12.7, 5.9, and 3 mGy). Images were reconstructed using a 1,024

resultsNoise magnitude values were lower with SR-DLR than with NR-DLR for level-2 (-27.6 ± 3.8%) and level-3 (-43.5 ± 1.4%), the opposite for level-1. Average NPS spatial frequency was higher with SR-DLR than with NR-DLR for all radiation dose levels for level-1 (55.9 ± 16.7%) and level-2 (20.1 ± 13.9%) and the opposite for level-3, except at 12.7 mGy. For both inserts, f

conclusionCompared to NR-DLR, SR-DLR improved spatial resolution and detectability of simulated abdominal lesions; image noise was reduced with SR-DLR only for level-2 and level-3, while image texture was better for level-1 and level-2. RELEVANCE STATEMENT: Super-resolution DLR with a 1,024 KEY POINTS: The performance of a new deep learning super-resolution image reconstruction algorithm (SR-DLR) was compared to a normal-resolution (NR)-DLR algorithm using an image-quality phantom for an abdominal energy-integrating detector CT protocol. SR-DLR with a 1,024

Indexed as

AlgorithmsDeep LearningImage Processing, Computer-AssistedPhantoms, ImagingRadiographic Image Interpretation, Computer-AssistedTomography, X-Ray ComputedHumansRadiation DosageSignal-To-Noise RatioArtificial intelligenceDeep learningImage enhancementImage processing (computer-assisted)Multidetector computed tomography

Identifiers

PMID41586868
PMCPMC12834881

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.