ArticleJournal of biomedical optics2026
Particle size distribution and concentration of Intralipid
Article in Journal of biomedical optics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Scattering properties of Intralipid modeled using dependent scattering theory.Journal of biomedical optics · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Significance: Intralipid Aim: We aim to determine the particle size distribution (PSD), concentration, and refractive index (RI) of particles in Intralipid Approach: Cryo-electron microscopy, three different flow cytometers, and microfluidic resistive pulse sensing were used to measure the size distribution and concentration of particles in Intralipid Results: The PSD, obtained from measurements of more than 10 million particles, spanned from 67 nm to over 2000 nm, with concentration decreasing continuously as diameter increased. The particle volume fraction calculated from the PSD deviated by less than 2% from the expected value, confirming the accuracy of the measurements. Optical parameters calculated from the PSD and RIs, including the scattering coefficient, phase function, anisotropy factor, and reduced scattering coefficient, showed good agreement with values reported in the literature. These parameters were also well described by empirical fits ( Conclusions: The accurate measurement of particle size, concentration, and RI of Intralipid
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.