ArticleStroke (Hoboken, N.J.)2024
Aristotle-Only Direct Aspiration First-Pass Technique (AO-ADAPT) for Endovascular Mechanical Thrombectomy: A Technical Series of a Novel Technique Demonstrating Safety and Efficacy.
Article in Stroke (Hoboken, N.J.), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed.
- Optimizing catheter centering enhances mechanical thrombectomy success: Performance difference in cases using novel macrowires versus traditional microwires.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2026Article
- Multicenter experience of the Monopoint reperfusion system in acute large vessel occlusion stroke thrombectomy.Journal of neurointerventional surgery · 2026Article
- First-pass efficacy with simplicity: Macrowire-only direct aspiration technique in posterior circulation mechanical thrombectomy.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025Article
- Macrowire-only direct aspiration first-pass technique for endovascular mechanical thrombectomy: Multicenter technical series using the 0.035″ aristotle Colossus wire.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025Article
- MINT Registry: Rationale and Study Design.Stroke (Hoboken, N.J.) · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: The introduction of soft, large-profile microwires has improved aspiration catheter delivery for intracranial large-vessel occlusions. The Aristotle-only direct aspiration first-pass technique (AO-ADAPT) uses the Aristotle 24 microwire to deliver a large-bore aspiration catheter to the target occlusion without a microcatheter. We characterized rates of technical success achieved using this technique for mechanical aspiration thrombectomy. Methods: A retrospective review of prospectively collected thrombectomy databases at 4 academic institutions identified patients undergoing procedures in which AO-ADAPT was used. Patient demographics, clinical considerations, technical details, and radiographic outcomes were collected. Rates of successful aspiration catheter delivery without adjunctive devices and of successful reperfusion (Thrombolysis in Cerebral Infarction≥2B) were collected. Results: Forty-five patients met inclusion criteria (mean age 72.2±13.2 years, 62.2% female; 71.1% M1 occlusions). With a first-line AO-ADAPT approach, 42/45 (93.3%) patients achieved Thrombolysis in Cerebral Infarction≥2B reperfusion, with first-pass recanalization in 26/45 (57.8%). We delivered the aspiration catheter to the target occlusion without adjunctive device in 35/45 (77.8%) patients. Of these, 29 (82.9%) underwent successful contact aspiration. This entire cohort (64.4% of the population) achieved Thrombolysis in Cerebral Infarction≥2B, with a mean time to reperfusion of 16 minutes and a first-pass recanalization rate of 66%. Of the 16 patients who did not achieve successful AO-ADAPT reperfusion, 6 needed a microcatheter for aspiration catheter delivery but underwent successful contact aspiration, 6 achieved microcatheter-free delivery but needed a stentriever for final recanalization, and 4 required both microcatheter for delivery and stentriever for final recanalization. No intracranial vascular complications occurred during the procedures; 1 patient (2.2%) experienced symptomatic intracranial hemorrhage secondary to reperfusion injury. Conclusion: The AO-ADAPT approach to mechanical thrombectomy safely and effectively achieved reperfusion for patients with large-vessel occlusions, with first-pass success and successful recanalization rates comparable with other techniques. For most cases in this series, this technique obviated the need for a microcatheter and/or stentriever.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.