ArticleResearch in diagnostic and interventional imaging2025
Displacement of intraorbital ferromagnetic foreign bodies induced by magnetic resonance imaging: Quantification using an animal model.
Article in Research in diagnostic and interventional imaging, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Rationale and objectives: The presence of ferromagnetic foreign bodies in the intraorbital area, eyelids, or intraorbital fat of an examined subject represents a contraindication to magnetic resonance imaging (MRI). We sought to measure the displacement of one or two intraocular and intraorbital ferromagnetic foreign bodies in ex vivo porcine heads following 1.5 T MRI scan compared to 5-min walk test. Materials and methods: In this ex-vivo controlled laboratory study, a total of 48 1-, 2-, and 4-mm steel balls were surgically implanted into suprachoroidal, intraorbital fat, intrapalpebral, and intravitreal locations of 36 fresh porcine heads. Ferromagnetic foreign bodies displacement was measured by comparing computed tomography scan before and after both a 5-min walk test to simulate handling-related movement and 1.5 T MRI scan. Comparison of groups was performed using the non-parametric Mann-Whitney-Wilcoxon test. Results: Global median displacement after 5-min walk test was 0.8 mm. Compared to the control group, the ferromagnetic foreign bodies displacement after MRI was significant for the suprachoroidal location with single ferromagnetic foreign body (2.3 mm, Conclusion: Ferromagnetic foreign body displacements after 1.5 T magnetic field exposition were not significant for extraocular intrapalpebral and intraorbital fat locations. Neither were there significant displacements for 1-mm ferromagnetic foreign body, irrespective of the location. On the other hand, the presence of two objects increased the displacement of 2- and 4-mm ferromagnetic foreign bodies.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.