Evidence map›Paper›PMID 41584542›Full record

ArticleJSES international2025

Optimal nerve release range and transposition distance in anterior ulnar nerve transposition for cubital tunnel syndrome: an anatomical study.

Kohei Hirukawa, Koji Sukegawa, Yukie Metoki, Takuya Tada, Tomomi Mizuhashi, Kentaro Uchida, Kenji Onuma, Yuya Otake, Motoyuki Ogawa, Gen Inoue and 1 more

Abstract read
In one paragraph

Article in JSES international, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Kohei HirukawaDepartment of Orthopedic Surgery, Kitasato University School of Medicine, Sagamihara City, Japan.
Koji SukegawaDepartment of Orthopedic Surgery, Kitasato University School of Medicine, Sagamihara City, Japan.
Yukie MetokiDepartment of Orthopedic Surgery, Kitasato University School of Medicine, Sagamihara City, Japan.
Takuya TadaDepartment of Orthopedic Surgery, Kitasato University School of Medicine, Sagamihara City, Japan.
Tomomi MizuhashiDepartment of Graduate School of Medical Sciences, Kitasato University, Sagamihara City, Japan.
Kentaro UchidaDepartment of Orthopedic Surgery, Kitasato University School of Medicine, Sagamihara City, Japan.
Kenji OnumaDepartment of Orthopedic Surgery, Kitasato University School of Medicine, Sagamihara City, Japan.
Yuya OtakeDepartment of Orthopedic Surgery, Kitasato University School of Medicine, Sagamihara City, Japan.
Motoyuki OgawaDepartment of Clinical Anatomy, Research and Development Center for Medical Education, Kitasato University School of Medicine, Sagamihara City, Japan.
Gen InoueDepartment of Orthopedic Surgery, Kitasato University School of Medicine, Sagamihara City, Japan.
Masashi TakasoDepartment of Orthopedic Surgery, Kitasato University School of Medicine, Sagamihara City, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Cubital tunnel syndrome, the second most common entrapment neuropathy, results from ulnar nerve compression at the medial epicondyle (ME). Conservative treatment often fails, requiring surgery. Transposition is an effective but invasive procedure, necessitating precise anatomical guidelines. We aimed to investigate the optimal anatomical measurements for ulnar nerve transposition to facilitate standardization of the technique. Methods: We examined 12 upper limbs from 6 fresh-frozen cadavers with elbows flexed at 60° and forearms supinated. The optimal transposition distance was defined as the distance from the ME to where the ulnar and median nerves run parallel. We measured this distance; pivot points A and B (where the ulnar nerve's course changes after transposition); crossing points over the medial intermuscular septum and flexors (A', B'); and ulnar nerve branch positions from the inferior border of the ME. Results: After excluding 3 outliers using the interquartile range method, 10 limbs were analyzed. The transposition distance was 16.6 ± 3.3 mm. Pivot points A and B were 53.8 ± 6.5 mm and 50.2 ± 9.1 mm from the ME. Crossing points A' and B' were 39.6 ± 7.9 mm and 40.2 ± 6.7 mm. Nerve branches were 21.1 ± 6.0 mm, 32.4 ± 14.8 mm, and 50.9 ± 24.6 mm from the inferior border of the ME. Conclusion: Anterior transposition shifts the ulnar nerve 17 mm anterior to the ME. To prevent kinking, dissection should extend 54 mm proximally and 50 mm distally, totaling approximately 105 mm. These measurements can guide intraoperative planning and emphasize the need for direct visualization to ensure safe and effective anterior transposition.

Indexed as

Anterior transpositionCubital tunnelElbow jointUlnar nerve

Identifiers

PMID41584542
PMCPMC12828199

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.