Evidence map›Paper›PMID 41584286›Full record

ArticleFrontiers in cardiovascular medicine2025

Real-world procedural and clinical outcomes of contemporary balloon-expandable and self-expandable TAVR systems: a single-center experience.

Mattia Vinciguerra, Andrea Spadafora, Alessandro Iaccarino, Fabio Miraldi, Eduardo Vitagliano, Antonio De Bellis, Ernesto Greco

Abstract read
In one paragraph

Article in Frontiers in cardiovascular medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Mattia VinciguerraDepartment of Clinical, Internal, Anesthesiology and Cardiovascular Sciences, Umberto I Hospital, Sapienza University of Rome, Rome, Italy.
Andrea SpadaforaDepartment of Cardiology and Cardiac Surgery, Casa di Cura "S. Michele", Caserta, Italy.
Alessandro IaccarinoDepartment of Cardiology and Cardiac Surgery, Casa di Cura "S. Michele", Caserta, Italy.
Fabio MiraldiDepartment of Clinical, Internal, Anesthesiology and Cardiovascular Sciences, Umberto I Hospital, Sapienza University of Rome, Rome, Italy.
Eduardo VitaglianoDepartment of Cardiology and Cardiac Surgery, Casa di Cura "S. Michele", Caserta, Italy.
Antonio De BellisDepartment of Cardiology and Cardiac Surgery, Casa di Cura "S. Michele", Caserta, Italy.
Ernesto GrecoDepartment of Health and Life Sciences, European University of Rome, Rome, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Transcatheter aortic valve replacement (TAVR) is rapidly becoming the preferred treatment for patients with severe aortic stenosis across different surgical risk profiles. However, the comparative performance of contemporary balloon-expandable valves (BEVs) and self-expandable valves (SEVs) in real-world practice remains debated. Objectives: To evaluate procedural and postoperative outcomes associated with different contemporary TAVR systems in a consecutive cohort of patients treated at a single center. Methods: We retrospectively analyzed 366 consecutive patients with symptomatic severe aortic stenosis and high surgical risk who underwent TAVR at Casa di Cura San Michele (Maddaloni, Italy) between January 2019 and October 2024. Patient baseline characteristics, procedural data, and in-hospital outcomes were collected and compared across different TAVR systems. Results: Among implanted prostheses, 71.0% were SEVs (Accurate Neo, Evolut R/Pro, Portico, Allegra) and 28.7% were BEVs (Sapien 3, Myval). BEVs were associated with significantly higher post-procedural transvalvular gradients (11.7 vs. 8.5 mmHg, Conclusion: In a real-world, single-center cohort, both BEVs and SEVs provided favorable outcomes. While BEVs demonstrated superior sealing properties with fewer paravalvular leaks, SEVs were associated with lower postoperative gradients. Careful consideration of anatomical and procedural factors remains essential for optimizing outcomes with contemporary TAVR systems.

Indexed as

balloon-expandableparavalvular leaksSAVRself-expandableTAVR

Identifiers

PMID41584286
PMCPMC12827654

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.