ArticleJournal of hand surgery global online2026
Intramedullary Threaded Nail Versus Dorsal Plate and Screw Fixation of Comminuted Metacarpal Shaft Fractures: A Cadaveric Biomechanical Study.
Article in Journal of hand surgery global online, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- A Biomechanical Analysis of Intramedullary Threaded Nail Fixation and Dorsal Plate and Screw Fixation for Metacarpal Base Fractures.Journal of hand surgery global online · 2027Article
- Intramedullary Headless Screw Feasibility for Anatomical Reduction in II-V Metacarpal Fractures: A CT-Based Morphometric Study.Journal of clinical medicine · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: Indications are expanding for the use of intramedullary threaded nail (IMTN) fixation in metacarpal fractures. We hypothesized that IMTN fixation would have superior bending stiffness compared to dorsal plate and screw fixation and provide sufficient stability to withstand cyclic loading comparable with early range of motion. Methods: Index, long, ring, and small finger metacarpals were harvested from matched pair cadaveric hands. A midshaft 1.75 mm transverse gap was created to simulate a comminuted fracture. Specimens were randomized into two groups for fixation with either a retrograde IMTN or dorsal plate and screws. Specimens underwent three-point bend testing with an Instron. Each specimen was cyclically loaded at 70 N for 2,000 cycles (composite grasp), followed by 120 N for 2,000 cycles (tip pinch). Specimens were then loaded to failure. Outcomes included cycles to failure, bending stiffness, peak load to failure, and location of failure. Results: Bending stiffness was significantly greater in the IMTN group compared to the plate group (136.71 ± 24.19 N/mm vs 39.89 ± 14.08 N/mm). Peak load to failure was greater in the plate group, but this difference was not statistically significant (365.33 ± 79.85 N vs 598.11 ± 372.76 N). During the cyclic loading phases, all specimens in the IMTN group completed the 70 N and 120 N loading phases without failure. In the plate group, two of nine specimens progressed to catastrophic failure during the 120 N cyclic loading phase. Conclusions: In a comminuted metacarpal shaft fracture model, IMTN fixation had significantly greater bending stiffness and more consistent load to failure characteristics compared to dorsal plate and screw fixation. Clinical relevance: IMTN fixation provided sufficient stability in comminuted metacarpal shaft fractures to withstand cyclic forces consistent with early range of motion, whereas dorsal plate and screw fixation demonstrated more variable results.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.