Evidence map›Paper›PMID 41583677›Full record

ArticleStroke (Hoboken, N.J.)2023

Manual and Oscillometric Blood Pressure in tPA-Treated Acute Ischemic Stroke: What Constitutes Agreement?

Mary A Grove, Mani Paliwal, Anne Shearin, Jane Kaiser, Eun Sun Koo, Danielle Howey, Michele Galati, Bozena Czekalski, Jennifer Dumawal, Briana DeCarvalho and 4 more

Abstract read
In one paragraph

Article in Stroke (Hoboken, N.J.), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

Mary A GroveHackensack Meridian Health Edison NJ.ORCID https://orcid.org/0000-0002-2281-7746
Mani PaliwalHackensack Meridian Health Edison NJ.
Anne ShearinUniversity of Tennessee College of Nursing Memphis TN.
Jane KaiserOcean University Medical Center Brick NJ.
Eun Sun KooJersey Shore University Medical Center Neptune NJ.
Danielle HoweyOcean University Medical Center Brick NJ.
Michele GalatiSouthern Ocean Medical Center Manahawkin NJ.
Bozena CzekalskiRiverview Medical Center Red Bank NJ.
Jennifer DumawalBayshore Medical Center Holmdel NJ.
Briana DeCarvalhoJFK Medical Center Edison NJ.
Jackie DwyerJersey Shore University Medical Center Neptune NJ.
Georgios TsivgoulisNational and Kapodistrian University of Athens Athens Greece.
Andrei V AlexandrovBanner University Medical Center and University of Arizona Phoenix AZ.
Anne W AlexandrovUniversity of Tennessee Health Science Center Memphis TN.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Automatic noninvasive oscillometric blood pressure (NIBP) devices measure mean arterial pressure (MAP); systolic and diastolic blood pressure (SBP, DBP) are algorithmically derived from MAP. The most invalid NIBP measure is SBP, yet stroke practitioners use it to manage blood pressure (BP) in accordance with thrombolysis guidelines. We determined agreement between SBP, DBP, and MAP measured manually and by NIBP in patients treated with alteplase. Methods: A multisite prospective observational study of NIBP and manual BP agreement was conducted in patients treated with alteplase immediately after bolus and infusion initiation using methods established in guidelines for the assessment of device agreement. Dual auscultatory stethoscopes were used by 2 investigators to ensure agreement with each manual BP variable and MAP was calculated using the standard formula for manual BP measures. Data were analyzed using Bland-Altman analyses and Lin concordance correlation coefficient. Results: A total of 7 hospitals participated, collecting 5 sets of manual/NIBP BPs in 95 patients treated with alteplase (475 paired measures). Range in limits of agreement were SBP: -28.91 to 21.41 mmHg with Lin's concordance correlation coefficient 0.8; DBP: -21.0 to 19.0 mmHg with Lin's concordance correlation coefficient 0.69; and MAP: -27.5 to 16.5 mmHg with Lin's concordance correlation coefficient 0.7. There was no difference in device agreement by BP device manufacturer brand. Differences in SBP, DBP, and MAP between NIBP and manual sphygmomanometry failed to reach guideline recommendations requiring 80% of measures to fall within a 5 mmHg difference and 95% of measures to fall within a 10 mmHg difference. Conclusion: NIBP devices produce significantly different BP measures then manual sphygmomanometry auscultated BP. Because NIBP devices rely on the MAP and do not directly measure SBP and DBP, definition of what constitutes safe MAP boundaries in patients treated with alteplase should be determined when automatic BP measurement is used in clinical practice.

Indexed as

acute ischemic strokealteplasebland‐altman measures of agreementblood pressurelimits of agreementmean arterial pressurenoninvasive oscillometric blood pressure

Identifiers

PMID41583677
PMCPMC12778675

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.