Evidence map›Paper›PMID 41583352›Full record

ArticleEndoscopic ultrasound

Feasibility of thin convex probe EBUS scope for the diagnosis of peripheral pulmonary lesions.

Si Chen, Hao Ji, Han Yang, Shuaiyang Liu, Houteng Xi, Lijun Yan, Jiayuan Sun

Abstract read
In one paragraph

Article in Endoscopic ultrasound. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. Review
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Si ChenDepartment of Respiratory Endoscopy, Department of Respiratory and Critical Care Medicine, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai Engineering Research Center of Respiratory Endoscopy, Shanghai, China.
Hao JiDepartment of Respiratory and Critical Care Medicine, Shanghai Chest Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200030, China.
Han YangDepartment of Respiratory Endoscopy, Department of Respiratory and Critical Care Medicine, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai Engineering Research Center of Respiratory Endoscopy, Shanghai, China.
Shuaiyang LiuDepartment of Respiratory Endoscopy, Department of Respiratory and Critical Care Medicine, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai Engineering Research Center of Respiratory Endoscopy, Shanghai, China.
Houteng XiDepartment of Respiratory Endoscopy, Department of Respiratory and Critical Care Medicine, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai Engineering Research Center of Respiratory Endoscopy, Shanghai, China.
Lijun YanDepartment of Respiratory Endoscopy, Department of Respiratory and Critical Care Medicine, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai Engineering Research Center of Respiratory Endoscopy, Shanghai, China.
Jiayuan SunDepartment of Respiratory Endoscopy, Department of Respiratory and Critical Care Medicine, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai Engineering Research Center of Respiratory Endoscopy, Shanghai, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and Objectives: Despite the emergence of advanced ancillary technologies, the transbronchial method to peripheral pulmonary lesions (PPLs) remains a challenge for bronchoscopists. The objective of the study is to assess the diagnostic value and safety of a novel thin Convex Probe Endobronchial Ultrasound (TCP-EBUS) scope in transbronchial needle aspiration (TBNA) for PPLs suspicious of malignancy. Methods: This single-center feasibility study prospectively enrolled patients with PPLs between August 2022 and January 2023. All lesions were biopsied by EBUS-TBNA using the novel TCP-EBUS scope (BF-UC290F, Olympus) and the prototype 22G aspiration needle (Vizishot2 22G, Olympus). The primary end point was the diagnostic yield. Results: Thirty-three subjects were evaluated, and 30 subjects were included in the final analysis. The mean patients' age was 62.4 ± 10.2 years, and 60% were male. The mean lesion size was 25.7 ± 6.8 mm, and 22 nodules were ≤30 mm. PPLs were situated adjacent to the subsegmental or sub-subsegmental bronchi (25 and 5, respectively), and the EBUS scope was advanced into segmental or subsegmental bronchi (12 and 18, respectively). Average number of punctures was 3.8 ± 1.3. Adequate specimens were obtained in all 30 (100%) of the cases. The overall diagnostic yield was 90% (27/30). No serious adverse events were observed. Conclusions: The TCP-EBUS has decent accessibility to more distal intrapulmonary lesions. TCP-EBUS-TBNA is a safe real-time procedure with a high sensitivity for malignant PPLs in the inner two-thirds of the lung, irrespective of the presence of a bronchus sign.

Indexed as

Computed tomography (CT)Flexible bronchoscope (FB)Peripheral pulmonary lesions (PPLs)Thin convex probe endobronchial ultrasonography (TCP-EBUS)Transbronchial needle aspiration (TBNA)Transthoracic needle aspiration (TTNA)

Identifiers

PMID41583352
PMCPMC12829674

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.