Evidence map›Paper›PMID 41583137›Full record

ArticleCureus2025

Assessing the Validity and Reliability of a Markerless Motion Capture System for Sagittal-Plane Gait Range of Motion.

Tsuyoshi Ohmura, Satoshi Kojima, Toshiki Azuma, Kei Narui, Sayaka Futatsuya, Saki Tsuchida, Tomoyuki Maruo, Katsushi Suwa

Abstract read
In one paragraph

Article in Cureus, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Tsuyoshi OhmuraDepartment of Rehabilitation, Keiju Kanazawa Hospital, Kanazawa, JPN.
Satoshi KojimaRehabilitation Science, Graduate School of Rehabilitation, Kinjo University, Hakusan, JPN.
Toshiki AzumaRehabilitation Medicine, Kinjo University, Hakusan, JPN.
Kei NaruiDepartment of Rehabilitation, Kanazawa Izumigaoka Watanabe Clinic, Kanazawa, JPN.
Sayaka FutatsuyaDepartment of Rehabilitation, Tanakamachi Onsen Care Center, Kanazawa, JPN.
Saki TsuchidaDepartment of Rehabilitation, Kanazawa Minami Care Center, Kanazawa, JPN.
Tomoyuki MaruoRehabilitation, Nara Child Therapeutic School BELIEVE, Yamato-Koriyama, JPN.
Katsushi SuwaDepartment of Rehabilitation, Keiju Kanazawa Hospital, Kanazawa, JPN.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionOptical three-dimensional (3D) motion capture systems and inertial measurement unit (IMU)-based systems provide accurate kinematic measurements, yet both remain costly and require complex setups. Artificial intelligence (AI)-driven markerless systems that operate with a single smartphone offer a practical alternative. In this study, we evaluated the validity and reliability of a markerless motion capture system (SPLYZA Motion; SPLYZA Inc., Shizuoka, METHODS AND ANALYSIS: Twenty healthy adults walked at a self-selected pace, and hip, knee, and ankle joint angles were recorded simultaneously using both systems. Joint angles were time-normalized, and waveform characteristics and peak values were compared. Associations were assessed using Spearman's rank correlation (ρ), agreement was examined using intraclass correlation [ICC(3,1)] with 95% confidence intervals (CIs), and proportional and fixed bias were evaluated using linear regression and Wilcoxon signed-rank tests. Agreement was further assessed using Bland-Altman analysis.

resultsSignificant positive correlations were observed for the hip (ρ = 0.913, p < 0.01), knee (ρ = 0.833, p < 0.01), and ankle (ρ = 0.721, p < 0.01). ICCs demonstrated excellent agreement for the hip (0.914; 95% CI: 0.906-0.920) and knee (0.934; 95% CI: 0.929-0.940) and good agreement for the ankle (0.723; 95% CI: 0.701-0.743). Root-mean-square error (RMSE) values (mean ± SD) were 7.73 ± 3.32° (hip), 7.48 ± 3.40° (knee), and 6.38 ± 2.44° (ankle). Bland-Altman plots indicated small biases for the hip and knee, with wider limits for the ankle near end-range positions.

conclusionSPLYZA Motion showed accuracy and reliability comparable to Ultium Motion within clinically acceptable limits. Minor ankle-related biases were small enough to avoid affecting clinical interpretation. Given its low cost and portability, this system provides a practical option for gait assessment in routine clinical and research environments. CLINICAL RELEVANCE: Minimal setup AI-based markerless motion capture enables a feasible clinical gait analysis.

Indexed as

artificial intelligencebiomechanicsgait analysisinertial measurement unitlower limb kinematicsmarkerless motion capturerange of motionreliabilitysmartphone applicationvalidity

Identifiers

PMID41583137
PMCPMC12823285

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.