Evidence map›Paper›PMID 41582979›Full record

ArticleStroke (Hoboken, N.J.)2022

Angiographic Predictors of Outcomes After Balloon Test Occlusion.

Aldo A Mendez, David J McCarthy, Daniel A Tonetti, Shashvat M Desai, James M Mountz, Paul A Gardner, Tudor G Jovin, Ashutosh P Jadhav

Abstract read
In one paragraph

Article in Stroke (Hoboken, N.J.), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Aldo A MendezDepartment of Neurology University of Pittsburgh Medical Center Pittsburgh PA.
David J McCarthyDepartment of Neurological Surgery University of Pittsburgh Medical Center Pittsburgh PA.
Daniel A TonettiDepartment of Neurological Surgery University of Pittsburgh Medical Center Pittsburgh PA.
Shashvat M DesaiDepartment of Neurology and Neurosurgery Barrow Neurological Institute Phoenix AZ.
James M MountzDepartment of Radiology University of Pittsburgh Medical Center Pittsburgh PA.
Paul A GardnerDepartment of Neurological Surgery University of Pittsburgh Medical Center Pittsburgh PA.
Tudor G JovinCooper Neurological Institute Cooper University Health Care Camden NJ.
Ashutosh P JadhavDepartment of Neurology and Neurosurgery Barrow Neurological Institute Phoenix AZ.ORCID https://orcid.org/0000-0002-9454-0678

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Balloon test occlusion (BTO) with adjunctive single-photon emission computed tomography has been used to predict tolerance after permanent internal carotid artery occlusion. Anatomic characteristics of the cerebral circulation might predict BTO outcomes and identify patients susceptible to test failure. Methods: We performed a single-center retrospective analysis of patients who underwent internal carotid artery BTO from July 2013 to June 2020. Patients who passed the clinical BTO underwent single-photon emission computed tomography imaging; technetium-99m-ethyl cysteinate dimer was injected intravenously after 15 to 30 minutes of occlusion and induced hypotension. The diameter of the vessels of the circle of Willis was measured angiographically. Single-photon emission computed tomography imaging hypoperfusion severity was classified as none, mild, low intermediate, high intermediate, and severe. A threshold vessel diameter with most predicted accuracy for BTO failure was created using the Youden index. The threshold value was tested in a logistic regression for prediction of BTO failure and accuracy as represented with a receiver operator curve. Results: Fifty-seven patients underwent BTO. Neoplasia was the most common indication (n=43, 75%). Twelve (21.1%) patients failed the clinical BTO. Contralateral dominant vertebral artery ( Conclusions: Angiographic findings can be used to predict BTO results. A small ipsilateral posterior communicating artery, and more significantly, a small ACom (<1.1 mm) can be used to identify patients who are likely to fail BTO.

Indexed as

angiographyballoon test occlusioncarotidSPECT

Identifiers

PMID41582979
PMCPMC12778850

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.