Evidence map›Paper›PMID 41582125›Full record

ArticleBMC musculoskeletal disorders2026

Structural design and biomechanical analysis of anti- subsidence gradient porous artificial vertebrae combined with a topology framework.

Peng Shang, Xinyu Wu, Rongqian Li, Benyuan Ma, Huapeng Wu, Yancheng Liu

Abstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Peng ShangHebei University of Technology, Tianjin, 300400, China. shangpeng@hebut.edu.cn.
Xinyu WuHebei University of Technology, Tianjin, 300400, China.
Rongqian LiHebei University of Technology, Tianjin, 300400, China.
Benyuan MaHebei University of Technology, Tianjin, 300400, China.
Huapeng WuLUT University, Lappeenranta, 53850, Finland. Huapeng.Wu@lut.fi.
Yancheng LiuTianjin University Tianjin Hospital, Tianjin, 300211, China.

Funding

Natural Science Fund Project of Hebei Province E2022202164
6 · The paper itself

Abstract

backgroundIn total disc replacement, mechanical failure and implant subsidence are significant complications after vertebral body replacement. Therefore, the design of a new artificial vertebral implant(AVI)that can ensure safety and improve prosthesis's subsidence has become a key challenge for spinal reconstruction.

methodsThis study involved designing a new AVI. Its exterior is a topological entity framework, and its interior is a gradient triply periodic minimal surface (TPMS) gyroid structure, which simulates cortical bone and cancellous bone, respectively. To enhance the safety and stability of the prosthesis. The biomechanical properties of AVIs under different physiological postures were analysed using the finite element method(FEM). The samples were prepared using selective laser melting (SLM), and the quasi-static compression and subsidence experiments were carried out for evaluation.

resultsThe peak stress of the topological gradient gyroid AVI was significantly lower than that of the traditional titanium mesh cage (TMC) and the truss + fluorite AVI, with a maximum reduction of 69.7%. Under all working conditions, the peak stress at the bone-implant interface of the vertebrae was 5.9% -14.1% lower than that of the truss + fluorite AVI and much lower than that of the TMC, with a decrease of 44.3%. Quasi-static compression experiments show that the maximum compression load of the topological gradient gyroid AVI is approximately 1.12 times greater than that of the truss + fluorite AVI and significantly greater than that of the TMC. This indicates that topological gradient gyroid AVI meets safety requirements. Additionally, its anti-subsidence ability is 20.4% higher than that of traditional porous AVI.

conclusionsCompared with traditional AVIs, the combination of topology optimization framework and gradient gyroid structure significantly improves the mechanical strength and subsidence resistance of the AVI, and can effectively reduce the stress concentration, which is expected to become the preferred scheme for spinal reconstruction.

Indexed as

Prostheses and ImplantsProsthesis DesignTotal Disc ReplacementBiomechanical PhenomenaFinite Element AnalysisHumansMaterials TestingPorosityStress, MechanicalArtificial vertebral implantBiomechanicsProsthetic reconstructionsSelective laser meltingTopology optimizationTriply periodic minimal surface

Identifiers

PMID41582125
PMCPMC12857080

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.