Isotropic three-dimensional cardiac cine imaging at 0.55T using stack-of-spiral sampling and four-dimensional iterative motion compensation.

Rajiv Ramasawmy, Ahsan Javed, Daniel A Herzka, Prakash Kumar, Krishna S Nayak, Robert J Lederman, Adrienne E Campbell-Washburn

Abstract read
In one paragraph

Article in Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Trial
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Rajiv RamasawmyLaboratory of Imaging Technology, Cardiovascular Branch, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA.
Ahsan JavedLaboratory of Imaging Technology, Cardiovascular Branch, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA.
Daniel A HerzkaDepartment of Radiology, Case Western Reserve University and University Hospitals, Cleveland Medical Center, Cleveland, Ohio, USA.
Prakash KumarMing Hsieh Department of Electrical and Computer Engineering, University of Southern California, Los Angeles, California, USA.
Krishna S NayakMing Hsieh Department of Electrical and Computer Engineering, University of Southern California, Los Angeles, California, USA.
Robert J LedermanLaboratory of Cardiovascular Interventions, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA.
Adrienne E Campbell-WashburnLaboratory of Imaging Technology, Cardiovascular Branch, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIsotropic three-dimensional (3D) cine imaging is an attractive one-stop-shop acquisition for cardiac MRI, as it can be arbitrarily resliced for the assessment of cardiac function and simplifies imaging workflows. Current free-breathing 3D cine approaches are hampered by long reconstruction times, and at lower-field strengths, by relatively long acquisition times. Here, we aim to maximize acquisition efficiency at 0.55T pairing two techniques; using a spiral acquisition with an optimized sampling distribution and a reconstruction incorporating data from all respiratory phases.

methodsWe implemented a 2 mm isotropic 3D cine approach on a prototype 0.55T scanner, using a 6 min stack-of-spiral balanced steady-state free precession (bSSFP) acquisition modified to use tiny-golden-angle in-plane rotations and distribute the k

resultsThe 4D iMoCo reconstruction required 20 min. The proposed variable-density sampling distribution reduced image artifacts, compared to a common linear sampling approach, and improved apparent signal-to-noise with relative increase of 221 ± 99%. Measurements had good agreement with the 2D Cartesian reference data with a left-ventricular volume bias of -2.5 ± 6.2% and 2.6 ± 10.4% in diastole and systole, respectively, and an ejection fraction bias of -3.5 ± 8.8%.

conclusionWe demonstrate an efficient free-breathing technique to produce 2 mm isotropic 3D cardiac images within a 6 min acquisition time and 20 min reconstruction time at 0.55T. Such a method could be a valuable clinical tool for cardiac imaging.

Indexed as

Image Interpretation, Computer-AssistedImaging, Three-DimensionalMagnetic Resonance Imaging, CineVentricular Function, LeftAdultArtifactsFemaleHumansMalePredictive Value of TestsReproducibility of ResultsRespirationTime Factors0.55T MRIFree-breathingIsotropicMotion-compensated reconstructionStack-of-spiralThree-dimensional cine

Identifiers

PMID41581732
PMCPMC13213869

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.