Evidence map›Paper›PMID 41577695›Full record

ArticleScientific reports2026

Correlation between lung ultrasound B lines and clinical as well as echocardiographic parameters in patients on maintenance hemodialysis.

Maulin K Shah, Reema D Patel, Rachit J Patel, Jyoti G Mannari, Mitesh Makwana, Vivek Kute, Jaishree Ganjiwale

Abstract read
In one paragraph

Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Interpretation of Lung Ultrasound in POCUS.Indian journal of pediatrics · 2026
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Maulin K ShahDepartment of Nephrology, Pramukh Swami Medical College, Shree Krishna Hospital, Bhaikaka University, Karamsad, Gujarat, India. mauls39@gmail.com.ORCID http://orcid.org/0000-0002-0065-013X
Reema D PatelDepartment of Medicine, Pramukh Swami Medical College, Shree Krishna Hospital, Bhaikaka University, Karamsad, Gujarat, India.ORCID http://orcid.org/0009-0004-8380-6890
Rachit J PatelDepartment of Critical Care Medicine, Shree Krishna Hospital, Bhaikaka University, Karamsad, Gujarat, India.ORCID http://orcid.org/0000-0001-5261-7027
Jyoti G MannariDepartment of Medicine, Pramukh Swami Medical College, Shree Krishna Hospital, Bhaikaka University, Karamsad, Gujarat, India.ORCID http://orcid.org/0000-0003-1868-8897
Mitesh MakwanaDepartment of Nephrology, Pramukh Swami Medical College, Shree Krishna Hospital, Bhaikaka University, Karamsad, Gujarat, India.ORCID http://orcid.org/0000-0001-8073-9435
Vivek KuteDepartment of Nephrology and Transplantation, Institute of Kidney Diseases and Research Center and Dr. H L Trivedi Institute of Transplantation Sciences (IKDRC- ITS), Civil Hospital, Ahmedabad, Gujarat, India.ORCID http://orcid.org/0000-0002-0002-2854
Jaishree GanjiwaleResearch & Development Cell & Department of Community Medicine, Pramukh Swami Medical College, Bhaikaka University, Karamsad, Gujarat, India.ORCID http://orcid.org/0000-0002-9940-0834

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Patients with chronic kidney disease undergoing hemodialysis are at an increased risk of cardiovascular complications due to volume overload. Lung ultrasound (LUS) has emerged as a non-invasive tool to assess extravascular lung water (EVLW) and manage fluid excess. This study aimed to validate LUS in a relatively asymptomatic day-care dialysis population and to correlate it with clinical parameters, ECHO/IVC metrics. This prospective pre-post intervention study was conducted in a dialysis unit, enrolling 93 eligible hemodialysis patients. The fluid status of all patients was evaluated by clinical examination, lung ultrasound, inferior vena cava (IVC) indices, and echocardiography pre and post-dialysis. The mean age was 48.20 ± 13.81 years with male predominance (n = 66,71%). Only 28 patients (30%) had NYHA class III dyspnea. Edema and lung crackles were observed in 5 (5.4%) and 8 patients (8.6%), respectively. The Mean Lung USG B lines pre- and post -dialysis were 3.527 ± 4.636 and 0.484 ± 1.419, respectively. Pre-HD lung USG B-lines showed significant correlations with edema (p = 0.05) and echocardiographic parameters, such as E/E' ratio (r = 0.35, p = 0.001), E velocity (r = 0.21, p = 0.04), and pulmonary pressure (r = 0.33, p = 0.001). A moderately positive correlation was also found between the maximum diameter of the IVC pre-dialysis and lung USG B-lines (P < 0.001). Lung USG is a promising technique for estimating EVLW in patients on dialysis. Significant correlations between pre-dialysis lung USG B-lines and echocardiographic measures of cardiac function, IVC maximum diameter and edema suggest a link between cardiac performance and volume status. This could complement clinical skills in determining dry weight.

Indexed as

EchocardiographyLungRenal DialysisRenal Insufficiency, ChronicAdultExtravascular Lung WaterFemaleHumansMaleMiddle AgedProspective StudiesPulmonary EdemaUltrasonographyVena Cava, InferiorB-linesChronic kidney diseaseHemodialysisLung ultrasoundPOCUSVolume overload

Identifiers

PMID41577695
PMCPMC12834980

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.