Evidence map›Paper›PMID 41576052›Full record

ArticlePloS one2026

Bond strength of thermoformed and 3D-printed aligners with universal primer versus one-step aligner adhesive with and without sandblasting: An in vitro study.

Viet Anh Nguyen, Viet Hoang, Thi Quynh Trang Vuong, Thi Nga Phung, Nghi Phan Bich Hoang

Abstract read
In one paragraph

Article in PloS one, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Viet Anh NguyenDepartment of Orthodontics, Faculty of Dentistry, Phenikaa University, Hanoi, Viet Nam.ORCID https://orcid.org/0000-0003-2185-6097
Viet HoangDepartment of Orthodontics and Pedodontics, Faculty of Dentistry, Van Lang University, Ho Chi Minh City, Vietnam.
Thi Quynh Trang VuongPrivate Practice, Viet Anh Orthodontic Clinic, Hanoi, Vietnam.
Thi Nga PhungPrivate Practice, Viet Anh Orthodontic Clinic, Hanoi, Vietnam.
Nghi Phan Bich HoangPrivate Practice, Viet Anh Orthodontic Clinic, Hanoi, Vietnam.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesChairside bonding of auxiliaries directly to aligners can avoid remanufacturing trays, but optimal protocols may be substrate-specific across modern thermoformed and 3D-printed materials. This study aimed to compare bond strength and failure mode across six representative aligner materials using a universal primer-orthodontic adhesive combination and a one-step aligner adhesive, with and without sandblasting. MATERIALS AND

methodsPolyethylene terephthalate glycol-modified (PETG), thermoplastic polyurethane (TPU), and glycol-modified polycyclohexylenedimethylene terephthalate (PCTG), together with three 3D-printed resins (TA-28, TC-85DAC, DCA), were prepared as 0.76-mm plates (n = 64). Specimens received alumina sandblasting or no treatment, then were bonded with either of two bonding strategies (n = 16). After thermocycling, bond strength was tested, and failures were scored by ARI. Two- and three-way ANOVA and proportional-odds modeling assessed effects (α = 0.05).

resultsBond strength showed significant main effects of material and sandblasting, with significant material-sandblasting and material-primer interactions. The primer main effect was not significant. Post hoc tests confirmed substrate-specific rankings. PETG with Bond Aligner (non-sandblasted) reached 26.71 MPa, while DCA with universal primer (sandblasted) reached 22.36 MPa. Sandblasting generally increased bond strength, with some exceptions. Failure mode was material-dependent and not completely parallel with bond strength.

conclusionsBonding efficacy depends on the aligner substrate. For thermoformed trays, a one-step aligner adhesive is preferable, with sandblasting contraindicated for PETG but advantageous for more elastic TPU and PCTG. For 3D-printed trays, a universal primer-orthodontic adhesive combination performs more consistently, with sandblasting benefiting DCA and TA-28, whereas TC-85DAC performs slightly better without it.

Indexed as

AdhesivesDental BondingPrinting, Three-DimensionalMaterials TestingPolyurethanesAdhesivesPolyurethanes

Identifiers

PMID41576052
PMCPMC12829832

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.