Impact of Inflow Ratio on a Double-Inflow Cavopulmonary Assist Device.

Simon Klocker, Leon Ballabani, Pascal Schmidt, Benjamin Torner, Bente Thamsen, Michael Röhrich, Michael Hübler, Daniel Zimpfer, Marcus Granegger

Abstract read
In one paragraph

Article in ASAIO journal (American Society for Artificial Internal Organs : 1992), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Simon KlockerFrom the Department of Cardiac and Thoracic Aortic Surgery, Medical University of Vienna, Austria.ORCID 0009-0007-4532-4198
Leon BallabaniFrom the Department of Cardiac and Thoracic Aortic Surgery, Medical University of Vienna, Austria.
Pascal SchmidtFrom the Department of Cardiac and Thoracic Aortic Surgery, Medical University of Vienna, Austria.
Benjamin TornerFrom the Department of Cardiac and Thoracic Aortic Surgery, Medical University of Vienna, Austria.ORCID 0000-0002-2732-1707
Bente ThamsenFrom the Department of Cardiac and Thoracic Aortic Surgery, Medical University of Vienna, Austria.ORCID 0000-0002-1300-7637
Michael RöhrichDepartment of Anesthesia, Critical Care and Pain Therapy, Medical University of Vienna, Austria.
Michael HüblerDepartment of Congenital and Pediatric Heart Surgery, Children's Heart Clinic, University Heart & Vascular Center Hamburg, Hamburg, Germany.
Daniel ZimpferFrom the Department of Cardiac and Thoracic Aortic Surgery, Medical University of Vienna, Austria.
Marcus GraneggerFrom the Department of Cardiac and Thoracic Aortic Surgery, Medical University of Vienna, Austria.ORCID 0000-0002-1425-1236

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The Fontan circulation is a palliative treatment for univentricular heart disease but is prone to progressive hemodynamic failure. To address this, a novel cavopulmonary assist device (CPAD) with dual inlets from the superior and inferior caval veins was developed. This study examines how varying inflow ratios (IRs) affect the CPAD's hydraulic performance, hemocompatibility, and flow estimation accuracy. Hydraulic performance, represented by the pressure head-flow (H-Q) characteristics, was experimentally and numerically assessed at different IRs. Hemolysis was evaluated experimentally at the nominal operating point (4 L/min, 2,500 RPM) for IRs of 1:1 and 1:3 (n = 5). Additionally, hemocompatibility-related metrics were determined numerically. Furthermore, the robustness of conventional flow estimation methods, based on motor current, pump speed, and viscosity, under varying IRs was examined. In vitro and in silico results indicated low variations in both hydraulic performance (ΔH < 2.2 mm Hg) and hemolysis(22.4% in measured Normalized Index of Hemolysis [NIH]; 4.9% in predicted damage index [DI]) across all investigated IRs. The flow estimation model based on motor current, rotational speed, and fluid viscosity showed high accuracy regardless of the IR, with root mean square error (RMSE) less than 0.148 L/min and R ² greater than 0.99. The analyzed double-inflow CPAD performed reliably across the investigated IRs, supporting its suitability for a broad patient population and enabling precise flow monitoring.

Indexed as

Fontan ProcedureHeart-Assist DevicesHemodynamicsHemolysisHumansModels, Cardiovascularcavopulmonary assist devicefailing Fontanflow estimatorinflow ratiorotodynamic blood pump

Identifiers

PMID41575875
PMCPMC13399723

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.