ArticleJournal of wrist surgery2026
Failure of Universal 2 Wrist Joint Replacements: A Retrieval Study.
Article in Journal of wrist surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Measurement of the wear volumes generated within retrieved magnetically controlled growing rods.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: The Universal 2 total wrist arthroplasty was one of the most common wrist replacements, but long-term results were disappointing, due to substantial damage to the polyethylene component and, in some cases, metallosis. The purpose of this research was to investigate the underlying reasons for this polyethylene damage. Materials and Methods: From a single clinical center, retrieval analysis was undertaken on six Universal 2 wrists and two additional polyethylene components. All components were analyzed at the macroscale and dimensional measurements of polyethylene components were undertaken. These were compared against known component orientation in vivo to identify areas of greatest material loss. Results: Of 62 Universal 2 wrists implanted, there was a tendency for smaller implants to be revised more frequently. Of the six explanted wrists, material loss was always noticeable on the ulnar side, and to a lesser extent in the dorsal direction. Five of eight polyethylene components had failed at the base of the ulnar-side blind hole. Smaller implants tended to have less thickness at the base of the blind holes, thus explaining the failure of smaller sizes. Discoloration and surface fatigue of explants indicated oxidation of components. Average time in vivo for the explants was 13.8 years which indicates the slow nature of polyethylene oxidation. All were revised due to loosening. All were implanted in rheumatoid patients with a mean age at surgery of 56.1 years. Three of the six Universal 2 wrists, all sized Extra Small, showed severe wear of the titanium alloy carpal component. Conclusion: Failure of the polyethylene components was due to a combination of inappropriate sterilization technique plus a design issue where polyethylene was thinnest on the smallest size components. Continued surveillance of patients implanted with Universal 2 wrists is recommended.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.