ArticleBioengineering & translational medicine2026
Transcatheter measurement of mitral valve coaptation pressure: A proof-of-concept study using animal models.
Article in Bioengineering & translational medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Transcatheter measurement of mitral valve coaptation pressure: A proof-of-concept study using animal models.Bioengineering & translational medicine · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
Mitral valve repair (MVr) is the preferred surgical treatment for primary mitral regurgitation; however, its success is limited by the lack of validated, accurate, and objective parameters for assessing the complete restoration of physiological mitral valve (MV) mechanics. Consequently, to address this challenge, intraoperative assessment of mitral valve coaptation pressure (MCP) has emerged as a promising approach. This study presents the first precise transcatheter measurement of MCP in animal hearts. Data were obtained using two custom-made force sensors: a 3Fr piezoresistive pressure catheter and a 15Fr flexible piezoelectric sensor. Experiments were conducted in both ex vivo (excised pig hearts activated by a pump) and in vivo (transseptal approach in a living pig) models. In a living pig with a healthy MV under normal hemodynamic conditions (peak systolic left ventricular pressure of 100 mmHg), the MCP ranged from 200 to 300 mmHg (25-40 kPa). Ex vivo experiments demonstrated that MCP was affected by transmitral pressure, mitral function changes (i.e., regurgitation), and MV morphology. These findings provide valuable insights into MV biomechanics and establish a solid foundation for developing medical devices to guide MVr procedures.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.