Evidence map›Paper›PMID 41572806›Full record

ArticleJournal of the American Chemical Society2026

A Critical Evaluation of the Limiting Current Density in Polymer Electrolytes: Interplay of Ion Transport, Mechanical Stability, and Conformal Li-Electrolyte Interfaces.

Philipp Röring, Jan Pleie, Andreas J Butzelaar, Gerrit M Overhoff, Christina Schmidt, Kerstin Neuhaus, Patrick Théato, Martin Winter, Gunther Brunklaus

Abstract read
In one paragraph

Article in Journal of the American Chemical Society, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Philipp RöringForschungszentrum Jülich GmbH, Helmholtz-Institute Münster (IMD-4), Corrensstraße 46, 48149 Münster, Germany.
Jan PleieForschungszentrum Jülich GmbH, Helmholtz-Institute Münster (IMD-4), Corrensstraße 46, 48149 Münster, Germany.
Andreas J ButzelaarKarlsruhe Institute of Technology (KIT), Institute for Chemical Technology and Polymer Chemistry (ITCP), Engesserstraße 18, 76131 Karlsruhe, Germany.ORCID 0000-0002-0843-2719
Gerrit M OverhoffForschungszentrum Jülich GmbH, Helmholtz-Institute Münster (IMD-4), Corrensstraße 46, 48149 Münster, Germany.
Christina SchmidtForschungszentrum Jülich GmbH, Helmholtz-Institute Münster (IMD-4), Corrensstraße 46, 48149 Münster, Germany.
Kerstin NeuhausForschungszentrum Jülich GmbH, Helmholtz-Institute Münster (IMD-4), Corrensstraße 46, 48149 Münster, Germany.
Patrick ThéatoKarlsruhe Institute of Technology (KIT), Institute for Chemical Technology and Polymer Chemistry (ITCP), Engesserstraße 18, 76131 Karlsruhe, Germany.ORCID 0000-0002-4562-9254
Martin WinterForschungszentrum Jülich GmbH, Helmholtz-Institute Münster (IMD-4), Corrensstraße 46, 48149 Münster, Germany.
Gunther BrunklausForschungszentrum Jülich GmbH, Helmholtz-Institute Münster (IMD-4), Corrensstraße 46, 48149 Münster, Germany.ORCID 0000-0003-0030-1383

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Solid-state batteries with lithium metal anodes are among the promising candidates to fulfill the actual requirements of growing energy demands in comparison to commercially available lithium-ion batteries, despite the current challenges of inhomogeneous lithium metal deposition upon cycling. In the present literature, the limiting current density is referred to as a key performance indicator for faster charging of solid-state batteries, though from a practical point of view, it is defined as the maximum endurable current density that might be applied without possible cell failure. In this study, we evaluate the obtained values of limiting current densities for lithium metal batteries operating with polymer electrolytes. Notably, we critically compare various experimental procedures to determine the actual limiting current density and discuss the impact of external factors such as scan rate, temperature, and applied cell pressure, thereby invoking model-type PEO-based electrolytes to examine available mechanical properties that may afford suppression of lithium dendrite formation. In fact, we demonstrate that experimentally derived limiting current densities are not intrinsic electrolyte characteristics but rather entities strongly dependent on the applied conditions and hence should ideally be determined based on different techniques to deliver meaningful data.

Identifiers

PMID41572806
PMCPMC12879923

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.