The influence of keratometry on the accuracy of intraocular lens formulas in highly myopic eyes.

Guang-Yue Li, Peng Zhao, Zhong-Yan Li, Zhao-Heng Yang, Meng Li, Jie Xu, Xiu-Hua Wan, Jing-Shang Zhang

Abstract read
In one paragraph

Article in BMC ophthalmology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Guang-Yue Li *Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing, 100730, China.
Peng Zhao *Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing, 100730, China.
Zhong-Yan LiBeijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing, 100730, China.
Zhao-Heng YangBeijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing, 100730, China.
Meng LiBeijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing, 100730, China.
Jie XuBeijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing, 100730, China.
Xiu-Hua WanBeijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing, 100730, China. wanxh@ccmu.edu.cn.
Jing-Shang ZhangBeijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing, 100730, China. jszhang@ccmu.edu.cn.

Funding

The Excellent Clinical Research Program for Research Wards BRWEP2024W172050109
6 · The paper itself

Abstract

backgroundTo investigate the influence of keratometry on the predictive accuracy of modern IOL formulas in determining optimal IOL power for cataract patients with high myopia.

methodsA total of 302 eyes from highly myopic patients who had undergone cataract surgery were divided into subgroups based on axial length AL and K. The predictive outcomes were to compare the accuracy of the following formulas: BU II, EVO 2.0, Haigis, Hoffer Q, Hoffer-QST, Holladay 2, K6, Kane, Pearl-DGS, SRK/T. For each formula, the ME, MAE, MedAE and the percentage of eyes with PEs within ± 0.25 D, ± 0.50 D, ± 0.75 D, and ± 1.00 D were analyzed.

resultsAmong all patients, the Hoffer QST formula achieved the lowest MAE (0.41 D), closely followed by EVO 2.0 (0.42 D). In the axial length subgroups, the Hoffer QST, BU II, and Haigis formulas achieved the lowest MAE (0.35 D) in the long AL group, while K6 achieved the lowest MAE (0.46 D) in the super-long AL group. For the extreme-long AL group, Hoffer QST demonstrated the lowest MAE at 0.41 D, closely followed by EVO 2.0 (0.44 D). In the keratometry subgroups, Hoffer QST consistently showed superior accuracy: in the flat-K group, it attained the lowest MAE (0.35 D) with BU II closely trailing (0.36 D); in the average-K group, it maintained the lowest MAE (0.41 D) followed by EVO 2.0 (0.43 D); and in the steep-K group, it achieved the lowest MAE (0.43 D), closely followed by EVO 2.0 (0.44 D).

conclusionsIn highly myopic eyes, modern IOL formulas demonstrate significantly superior predictive accuracy compared to traditional formulas for the different keratometry, with Hoffer QST and EVO 2.0 exhibiting the best performance in this study.

Indexed as

BiometryCorneaLenses, IntraocularMyopiaMyopia, DegenerativeOptics and PhotonicsRefraction, OcularAgedAxial Length, EyeFemaleHumansLens Implantation, IntraocularMaleMiddle AgedPhacoemulsificationRetrospective StudiesCataract surgeryFormulasHigh myopiaIntraocular lensKeratometry

Identifiers

PMID41572214
PMCPMC12908389

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.