Evidence map›Paper›PMID 41572069›Full record

ArticleEuropean journal of trauma and emergency surgery : official publication of the European Trauma Society2026

Modified Johannesburg technique sets the standard - superior biomechanical stability in chest tube fixation.

Johann Justus Fricke, Tobias Schöbel, Ric Meißner, Stefan Schleifenbaum, Christian Kleber, Isabella Metelmann, Sebastian Krämer

Abstract read
In one paragraph

Article in European journal of trauma and emergency surgery : official publication of the European Trauma Society, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Johann Justus Fricke *Department of Orthopedic, Trauma, and Plastic Surgery, University of Leipzig, Liebigstraße 20, 04103, Leipzig, Germany.
Tobias Schöbel *Department of Orthopedic, Trauma, and Plastic Surgery, University of Leipzig, Liebigstraße 20, 04103, Leipzig, Germany. tobias.schoebel@medizin.uni-leipzig.de.
Ric MeißnerDepartment of Orthopedic, Trauma, and Plastic Surgery, University of Leipzig, Liebigstraße 20, 04103, Leipzig, Germany.
Stefan SchleifenbaumDepartment of Orthopedic, Trauma, and Plastic Surgery, University of Leipzig, Liebigstraße 20, 04103, Leipzig, Germany.
Christian KleberDepartment of Orthopedic, Trauma, and Plastic Surgery, University of Leipzig, Liebigstraße 20, 04103, Leipzig, Germany.
Isabella Metelmann *Department of Visceral, Transplantation, Thoracic and Vascular Surgery, Leipzig University, Liebigstraße 20, 04013, Leipzig, Germany.
Sebastian Krämer *Department of Visceral, Transplantation, Thoracic and Vascular Surgery, Leipzig University, Liebigstraße 20, 04013, Leipzig, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundChest tube dislodgement is a frequent and potentially life-threatening complication after thoracic trauma. Reliable fixation is essential, particularly in emergency and combat casualty care. Several suture techniques exist, but comparative biomechanical evidence is limited.

methodsThis prospective biomechanical cadaveric study compared three fixation techniques-Purse String (PS), Roman Sandal (RS), and Modified Johannesburg (JO) technique -across three tube sizes (20, 24, 28 Charrière) and two materials (polyvinyl chloride (PVC) and silicone). A total of 360 tests were performed on porcine thoracic wall specimens under standardized conditions. Specimens were subjected to vertical load-to-failure testing with continuous measurement of force and elongation.

resultsThe Modified Johannesburg technique consistently demonstrated the highest pull-out strength across all tube sizes and materials, significantly outperforming both RS and PS (p < 0.0001). RS ranked second and showed significantly greater stability than PS in all conditions (p < 0.0001). Effect size analysis revealed large differences between JO and PS (r = 0.87) and between RS and PS (r = 0.50), and a medium effect between JO and RS (r = 0.36). PVC tubes provided significantly greater pull-out strength than silicone tubes (147.0 ± 54.2 N vs. 128.5 ± 42.2 N; p = 0.01071), although silicone tubes exhibited greater elongation prior to failure. Tube size had a modest influence on stability, with larger tubes tending toward higher pull-out strength, but pairwise differences did not reach significance. The predominant failure mechanism was suture rupture (78.9%), followed by tube rupture (11.1%), knot loosening (8.1%), and skin failure (1.9%).

conclusionsThe Modified Johannesburg Technique offers superior biomechanical stability for chest tube fixation, regardless of tube size or material. This technique should be considered the preferred method in high-risk environments, including military and emergency care, to minimize dislodgement and enhance patient safety.

Indexed as

Chest TubesSuture TechniquesThoracic InjuriesAnimalsBiomechanical PhenomenaCadaverHumansMaterials TestingProspective StudiesSwineBiomechanicsChest tubesCombat careEmergencyFixation techniquesSutureThoracic injuriesTrauma

Identifiers

PMID41572069
PMCPMC12827373

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.