ArticlePediatric radiology2026
Application value of dual-energy computed tomography virtual monoenergetic images for pediatric hand angiography.
Article in Pediatric radiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
backgroundWhile single-energy hand computed tomography angiography (CTA) often yields suboptimal visualization of distal vessels, dual-energy computed tomography (CT) with low-keV virtual monoenergetic image (VMI) reconstruction enhances small-vessel conspicuity.
objectiveTo evaluate the value of dual-energy CT VMIs in pediatric hand CTA. MATERIALS AND
methodsThis retrospective study included 49 pediatric patients. Seven image series per patient were generated from dual-energy data: an M_0.5 image (50% 70 kVp+50% tin-filtered 150 kVp), a 70-kVp image, and five VMIs at 40-80 keV (10-keV increments). Objective metrics (attenuation, vessel noise, signal-to-noise ratio, contrast-to-noise ratio) and subjective scores were assessed for five vessels: the radial artery, the ulnar artery, the common palmar digital artery, and the proximal and distal parts of the proper palmar digital artery. Subjective image quality was independently evaluated by two radiologists using a 4-point Likert scale.
resultsThe 40-keV VMIs provided the highest vascular attenuation across all vessels, albeit with the highest noise. Subjective scores for the radial, ulnar, and common palmar digital arteries showed no significant differences among the 40-keV, 50-keV, and 70-kVp series. However, for the small distal proper palmar digital arteries and total image quality, the 40-keV series was rated superior to the other series. No significant differences in image quality existed between the 70-kVp and 50-keV images.
conclusionFor pediatric hand CTA, 40-keV VMIs provide optimal vascular conspicuity for small distal vessels, yielding the highest diagnostic confidence and total image quality score, and this benefit outweighs the associated increase in vessel noise.
Indexed as
Identifiers
41569332What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.