Article in Journal of Korean Neurosurgical Society, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Hye Seok ParkDepartment of Neurosurgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea.
Jong Ha HwangDepartment of Neurosurgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea.
Sun Mo NamDepartment of Neurosurgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea.
So Young JiDepartment of Neurosurgery, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam, Korea.
Kihwan HwangDepartment of Neurosurgery, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam, Korea.
Min-Sung KimDepartment of Neurosurgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea.
Jung Ho HanDepartment of Neurosurgery, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam, Korea.
Yong Hwy KimDepartment of Neurosurgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea.
Chul-Kee ParkDepartment of Neurosurgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea.
Chae-Yong KimDepartment of Neurosurgery, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam, Korea.
Yoon Hwan ByunDepartment of Neurosurgery, SMG-SNU Boramae Medical Center, Seoul National University College of Medicine, Seoul, Korea.
Ho KangDepartment of Neurosurgery, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam, Korea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveThe aim of this study was to report the early clinical experience with stereotactic biopsy using the Medtronic Stealth Autoguide Cranial Robotic Guidance Platform, representing the first relevant clinical study in the Republic of Korea (ROK). We evaluated potential advantages and limitations related to workflow integration, instrument setup, procedural efficiency, accuracy, and safety.

methodsA retrospective case series was conducted across three centers in the ROK. From April to July 2025, 17 consecutive patients underwent frameless stereotactic biopsy using the Stealth Autoguide system. Data on demographics, operative time, and complications were collected, and descriptive analyses were performed.

resultsBiopsy using the Stealth Autoguide System was successfully completed in 16 of 17 patients. The median operative time was 48 minutes (interquartile range, 33-64), and the median target alignment error was 0.4 mm (interquartile range, 0.3-0.6). One case required conversion to the conventional manual method due to targeting inaccuracy. Three cases of asymptomatic intracerebral hemorrhage occurred, including one at the tissue-harvest site and two with cortical hemorrhage, all of which were managed conservatively.

conclusionThe Stealth Autoguide system facilitates a more efficient frameless stereotactic biopsy than conventional methods by reducing operative time, enhancing accuracy, and allowing for a smaller, muscle-sparing incision. However, some concerns remain, and further clinical validation is needed to define its optimal indications and safety profile.

Indexed as

Brain neoplasmsMinimally invasive surgeryNeedle biopsyRobotic-assisted surgeryStereotactic techniques

Identifiers

PMID41560496
PMCPMC13172786

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.