ArticleInternational journal of spine surgery2026
A Novel Concept and 3D Coupler for Robotic Correction of Spinal Deformities: In Vitro Experimental Testing.
Article in International journal of spine surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundCurrent techniques for surgical correction of spinal deformities impart realigning the deviated vertebrae along a rigid rod. Solid rods are a major restricting factor to vertebral manipulation, leading to incomplete, imprecise, and less predictable 3-dimensional (3D) correction. Additionally, forceful manual nonquantifiable maneuvers may result in potential implant failures and increased incidence of complications. We are introducing a machine-operated device for digitized segmental 6 degrees of freedom (6 DOF) correction of individual vertebral deviations.
methodsWe manufactured a 3D coupler incorporating multiple self-locking uniaxial joints. The device's precision was tested by comparing targeted vs delivered motions. For functionality testing, we used computed tomography-based 3D-printed vertebral models to verify the device's ability to manipulate the vertebra in each direction of motion.
resultsIn all tested motions, the coupler accurately and repeatedly delivered the predicted targeted motions. The device could mobilize 2 vertebral models relative to each other in 4 out of 6 DOF.
conclusionsThe novel 3D coupler can deliver machine-driven, precise, and predictable multiplanar motion; it could manipulate the vertebral model in rotation and translation. CLINICAL RELEVANCE: The novel device addresses a crucial unmet need in spinal surgery by offering digital precision, true 6 DOF correction, and supporting robotic execution of surgical actions. LEVEL OF EVIDENCE: 5:
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.