Evidence map›Paper›PMID 41557851›Full record

ArticleInvestigative radiology2026

High-Z Contrast Media for Coronary Photon-counting Detector CT Angiography: Improved Quantification of Calcified Stenoses.

Tristan T Demmert, Konstantin Klambauer, Bernhard Schmidt, Victor Mergen, Lukas J Moser, Philipp N Maintz, Thomas Allmendinger, Thomas Flohr, Hubertus Pietsch, Matthias Eberhard and 1 more

Abstract read
In one paragraph

Article in Investigative radiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Tristan T Demmert
Konstantin Klambauer
Bernhard Schmidt
Victor Mergen
Lukas J Moser
Philipp N Maintz
Thomas Allmendinger
Thomas Flohr
Hubertus Pietsch
Matthias Eberhard

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundBlooming artifacts from calcified plaques can obscure the vessel lumen, leading to overestimation of stenosis severity. Spectral coronary angiography with photon-counting detector CT (PCD-CT) provides virtual monoenergetic images (VMIs) for coronary artery disease assessment. While VMIs at high VMI energy levels reduce calcium blooming, iodine contrast is diminished, limiting diagnostic value. This study evaluated whether contrast media with an atomic number higher than iodine (high-Z) preserve vascular contrast using high VMI energy levels, thereby improving the accuracy of stenosis quantification.

methodsA phantom with 4 and 6 mm diameter rods to mimic small diameter vessels containing eccentric calcified plaques causing 25%, 50%, and 75% diameter stenoses was scanned with a dual-source PCD-CT system. Five different contrast media, including iodine, tungsten, holmium, hafnium, and bismuth, were tested. VMIs were reconstructed from 40 to 190 keV in 1-keV steps. Vessel attenuation, contrast-to-noise ratio (CNR), and stenoses were measured. Qualitative assessment of image quality was performed.

resultsIodine attenuation was high at lower VMI energy levels and dropped below 250 HU at >100 keV. Tungsten, holmium, hafnium, and bismuth maintained >250 HU attenuation throughout the entire energy range. Vessel CNR of iodine was high at lower and decreased at higher VMI energy levels, similar to the CNR of holmium and bismuth, though to a lesser extent. In distinction, CNRs of tungsten and hafnium were lower at lower VMI energy levels and increased to a relatively constant level at higher keV. Tungsten CNR increased with energy, approaching ~40 at high keV. Across all contrast media and stenosis degrees, stenoses were overestimated on low VMI energy levels (24% to 32.5% at 40 keV), while the degree of overestimation decreased at higher VMI energy levels (0% to 13.5% at 190 keV). At 190 keV, tungsten, hafnium, and bismuth showed ≤2.5% stenosis overestimation, compared with iodine (10% to 13.5%). Image quality varied between contrast media and energy levels: new very high-Z contrast media achieved higher scores, while iodine peaked at lower keV (55 to 70 keV) and, due to loss of contrast at higher energies, received the lowest overall scores.

conclusionsAs compared with iodine, very high-Z contrast media enable superior lumen definition and more accurate stenosis assessment, also at high VMI energy levels, which minimize calcium blooming.

Indexed as

Computed Tomography AngiographyContrast MediaCoronary AngiographyCoronary StenosisHumansPhantoms, ImagingPhotonsRadiographic Image EnhancementRadiographic Image Interpretation, Computer-AssistedReproducibility of ResultsSensitivity and SpecificityContrast Mediacalcificationcoronary stenosishigh-Z contrast mediaphantomplaques

Identifiers

PMID41557851
PMCPMC13317894

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.