Evidence map›Paper›PMID 41557080›Full record

ArticleMagma (New York, N.Y.)2026

Enhancing SNR in MRI at 7T using wearable coils, dielectric resonators, and dipole antennas.

Daniel Wenz, Jules Vliem, Elizaveta Shegurova, Mark Widmaier, Lijing Xin, Dimitrios C Karampinos, Irena Zivkovic

Erratum issuedAbstract read
In one paragraph

Article in Magma (New York, N.Y.), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

7 authors.

Daniel Wenz *CIBM Center for Biomedical Imaging, Lausanne, Switzerland. daniel.wenz@epfl.ch.
Jules Vliem *Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.
Elizaveta ShegurovaCIBM Center for Biomedical Imaging, Lausanne, Switzerland.
Mark WidmaierCIBM Center for Biomedical Imaging, Lausanne, Switzerland.
Lijing XinCIBM Center for Biomedical Imaging, Lausanne, Switzerland.
Dimitrios C KarampinosCIBM Center for Biomedical Imaging, Lausanne, Switzerland.
Irena ZivkovicDepartment of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands. i.zivkovic@tue.nl.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

motivationThe twisted-pair (TP) coil design is a promising strategy for developing novel, flexible, wearable MRI detectors that can provide SNR gains in various clinical applications of high-field MRI. We hypothesize that the TP coil's receive (Rx) sensitivity can be significantly increased by combining it with two complementary elements, such as dielectric resonators (DRs) and dipole antennas.

methodsTP coils were combined with DRs made of high-permittivity material (ε

resultsThe array combining all three types of elements (TP coils, DRs, and dipole antennas) provided the highest overall Rx performance; MR phantom experiments showed that integrating DRs with TP coils increased peripheral SNR by 250% and central SNR by 23% (for a total 38% gain in the center when also using dipole antennas in Rx). Human voxel model simulations confirmed that similar SNR gains can be achieved in vivo. Integrating DRs into TP coils also increased central Tx field efficiency by 4.6% and reduced the peak SAR

conclusionDRs and dipole antennas can significantly improve the overall Rx performance of TP coils. This concept can benefit MRI of the human lower extremity at 7 Tesla and encourage exploration of its utility for other clinical applications.

Indexed as

Magnetic Resonance ImagingWearable Electronic DevicesComputer SimulationEquipment DesignHumansImage Processing, Computer-AssistedPhantoms, ImagingSignal-To-Noise Ratio7TDielectric resonatorDipole antennaFlexible RF coilHigh-field MRIHigh-permittivity materialRF arrayUHFWearable RF coil

Identifiers

PMID41557080
PMCPMC13447474

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.