ArticleInterdisciplinary cardiovascular and thoracic surgery2026
From 3D Printing to Clinical Application: A Patient-Specific Venous Model to Assess the Endovascular Implementation of Single-Lung Perfusion with Blood Flow Occlusion.
Article in Interdisciplinary cardiovascular and thoracic surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesSelective pulmonary artery perfusion with blood flow occlusion (SPAP-BFO), an experimental endovascular technique, has shown potential to enhance pulmonary drug delivery to the lung. Therefore, it becomes a potential minimally invasive technique for lung cancer and pulmonary metastases. Prior studies predominantly used animal models which do not adequately replicate human vascular anatomy, leaving the clinical feasibility of SPAP-BFO underexplored. To address this gap, we developed a patient-specific 3D model of the human venous system to evaluate the technical feasibility of SPAP-BFO.
methodsA 1:1 scale 3D model of the human venous system was developed and printed based on CT scans of a patient. This model was connected to a perfusion system to simulate blood flow, enabling testing of the catheterization procedure under realistic clinical conditions. Two commercially available balloon catheters, Coda (Cook) and Reliant (Medtronic), were selected based on length and balloon diameter, and their feasibility of reaching and occluding the left and right pulmonary arteries were assessed.
resultsThe model effectively simulated human anatomy and blood flow, allowing for both visual and fluoroscopic assessment of the procedure. Both Coda and Reliant catheters successfully reached the target location, when introduced via the femoral vein, and occluded the left and right pulmonary arteries without physically blocking contralateral flow or extending beyond the first bifurcation.
conclusionsThis patient-specific 3D model provided a valuable platform to evaluate the clinical feasibility of SPAP-BFO. The Coda and Reliant balloon catheters demonstrated effective occlusion of the pulmonary arteries, supporting their potential use in SPAP-BFO procedures.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.