Temperature sensitivity analysis and service performance evaluation of aqueduct arch ring beam structures based on finite element method.
Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This study investigates the temperature sensitivity and service performance of aqueduct arch ring beam structures through comprehensive finite element analysis. A thermal-structural coupling model was developed to analyze temperature field distributions and structural response characteristics under various environmental conditions. The research reveals that temperature-induced stresses reach 40-60% of allowable limits, with maximum concentrations occurring at arch-beam connection regions. Seasonal temperature variations spanning 58 °C create significant thermal cycling effects that impact long-term structural durability. The comprehensive service performance evaluation model yields an overall condition rating of 73.0 (Good grade), identifying thermal fatigue resistance and durability as critical performance limitations. The arch crown experiences maximum temperature fluctuations with peak thermal stresses of 4.5 MPa during extreme heating conditions. The study establishes quantitative assessment frameworks for condition monitoring and provides engineering recommendations including enhanced thermal protection systems and temperature monitoring implementations. The findings support improved design methodologies and maintenance strategies for critical water infrastructure systems under environmental temperature effects.