ArticleBioactive materials2026
A large puncture closer of aortic wall by multi-memory actions with thrombo-hemodynamic control.
Article in Bioactive materials, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The vascular wall regulates the pattern and pressure of blood flow. In cardiovascular interventions, catheters are deployed by puncturing the vessel wall, without exception. Despite continuous progress, the outcomes remain highly operator-dependent, and large punctures with high-pressure bleeding continue to pose clinical challenges. As a translatable solution, this study introduces a shape memory vascular wall plug (VWP) that automates both the Body and Wing functions within a single component, supported by a Ring assembly to maximize pressure resistance. The VWP is deployed into a 6-mm puncture in a porcine thoracic aorta under peak blood pressure, and shape recovery is triggered by a 45°C saline flush to enable automated activation. Upon recovery, Body expansion combined with Ring compression tightly seals the puncture tract. The curved Wing induces hemostatic sealing and then flattens to maintain healthy blood flow and physiologic pressures. The VWP achieves suturing-level performance in aortic puncture closure, demonstrating effective hemostasis, patency, and endothelialization. The flow-blockage ratio required to balance hemostasis with hemodynamics is computationally modeled and validated using whole-blood microfluidics. Pressure resistance is maximized by tuning Ring strain through polymer blending, indicating multi-level strategies in polymer, device design, and memory function to advance the vascular closure technology.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.