ArticleJournal of dentistry2026
Effect of internal connection parameters on the fatigue limit of narrow-diameter implants - a finite element study.
Article in Journal of dentistry, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Distinct Structural Determinants of Failure in Morse Taper and Internal Hex Implant Systems.Journal of functional biomaterials · 2026Article
- Multiscale bone remodeling in COVID-19: from osteoimmune signaling to structural and mechanical impairment.Frontiers in bioengineering and biotechnology · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
objectiveTo evaluate the influence of internal connection parameters on the fatigue limit of narrow-diameter dental implants using finite element analysis (FEA).
methodsA narrow-diameter dental implant (3.0 mm, Morse taper connection) and its corresponding abutment and screw were scanned using micro-computed tomography (micro-CT). High-resolution 3D models were reconstructed (Simpleware, Synopsis), and six geometric parameters defining the internal connection were extracted. A reference 3D assembly was built in SolidWorks, and systematic dimensional variations (±20%) of the six design parameters were introduced based on a Taguchi orthogonal array (DOE++, Reliasoft), resulting in 27 modified assemblies. Static FEA was performed in ABAQUS according to ISO 14,801:2016 geometry. Fatigue performance was estimated using Fe-safe software, and sensitivity analyses were conducted to identify the most influential parameters on the predicted fatigue limit.
resultsThe reference model presented a fatigue limit of 193 N. Dimensional optimization based on FEA improved the fatigue limit up to 295 N, representing a 52.3% increase compared to the original design, with the cervical opening diameter (CID) showing a significant effect on fatigue performance.
conclusionsSystematic variation of internal connection geometry significantly affected the fatigue resistance of narrow-diameter implants. Identifying critical parameters enables the development of more durable and reliable implant-abutment assemblies, maximizing the treatment success in anatomically compromised sites. CLINICAL SIGNIFICANCE: Optimizing the internal geometry of narrow-diameter implants can improve load distribution, minimize mechanical complications, and increase the longevity of implant-supported rehabilitations in areas with reduced bone volume.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials