ArticleBMC oral health2026
A comparison of the released forces from three different types of nickel-titanium wires at three different deflection positions: an in-vitro study.
Article in BMC oral health, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionNiTi archwires are distinguished by their ability to deliver gentle, continuous forces over a wide activation range, over time, their crystalline structure has evolved: beginning with conventional NiTi, progressing to super-elastic variants, and then advancing to heat-activated. In this study, we examined three 0.016″ × 0.022″ NiTi rectangular wires: (1) super-elastic NT3 SE®, (2) heat-activated Thermal Ti-D® (active at ~ 25 °C), and (3) heat-activated Thermal Ti-Lite® (~ 35 °C)—by measuring their force release at molar, premolar, and incisor positions to determine whether unloading forces differ by location. MATERIALS AND
methodsA randomized, in-vitro trial was conducted at Aleppo University. Each group included six 30 mm wire sections for each wire type and position (total n = 18 per position). A three-point bending test at 37 °C (Deflection: 3.1 mm at 1 mm/min over a 10 mm span) measured unloading forces at 0.5, 1-, 2-, and 3-mm. Plateau length (3 to 0.5 mm), average force, and slope were recorded. Data were analyzed using one-way ANOVA with post-hoc Sidak’s test; reliability was confirmed via Pearson correlation (r = 0.877).
resultsNT3 SE® and Thermal Ti-D® wires showed similar unloading forces across positions (molar: 2.65 ± 0.11, 1.60 ± 0.18, 1.40 ± 0.18, 1.09 ± 0.19 N; incisor: 2.55 ± 0.12, 1.50 ± 0.18, 1.30 ± 0.18, 1.00 ± 0.15 N at 3, 2, 1, and 0.5 mm, respectively), with molar values approximately 10% higher than incisor values; differences were not statistically significant (p > 0.05), and 95% confidence intervals overlapped. Thermal Ti Lite® wires exhibited significantly lower forces overall and clear site-dependent differences (molar: 2.28 ± 0.21, 1.76 ± 0.10, 0.52 ± 0.09, 0.56 ± 0.14 N; premolar: 1.92 ± 0.12, 0.56 ± 0.10, 0.32 ± 0.09, 0.31 ± 0.09 N; incisor: 1.57 ± 0.20, 0.36 ± 0.10, 0.12 ± 0.09, 0.12 ± 0.09 N at 3, 2, 1, and 0.5 mm, respectively), with molar forces on average 50% higher than premolar and 70% higher than incisor values (p < 0.05); average and slope also varied significantly by position, though plateau lengths were consistent—only Ti Lite® showed positional force variability.
conclusionThermal Ti-Lite® archwires, with higher austenite-finish temperature (~ 34 °C), demonstrated significant positional force differences, suggesting their potential for site-specific biomechanical control. In contrast, NT3-SE® and Thermal Ti-D® provided uniform force profiles across arch positions. Considering crystalline transformation temperatures and anatomical variation may improve clinical force application during alignment.
Indexed as