Evidence map›Paper›PMID 41543952›Full record

ArticleIEEE transactions on medical imaging2026

A High-Performance Self-Collimation SPECT for Small Animal Imaging.

Debin Zhang, Zhenlei Lyu, Tianpeng Xu, Peng Fan, Zerui Yu, Qiqi Ye, Yifan Hu, Jing Wu, Qingyang Wei, Xin Zhang and 8 more

Abstract read
In one paragraph

Article in IEEE transactions on medical imaging, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

18 authors.

Debin Zhang
Zhenlei Lyu
Tianpeng Xu
Peng Fan
Zerui Yu
Qiqi Ye
Yifan Hu
Jing Wu
Qingyang Wei
Xin Zhang
Qianqian Gan
Yang Xu
Li Wang
Rutao Yao
Min-Fu Yang
Zuo-Xiang He
Yaqiang Liu
Tianyu Ma

Funding

Self-collimating Single Photon Emission Breast Tomography System with Three-Dimensional Sparse Position-Sensitive DetectorsR21EB032993 · NIBIB · STATE UNIVERSITY OF NEW YORK AT BUFFALO · PI YAO, RUTAO · 2022 to 2024
$611k
NIBIB NIH HHS R21 EB032993
6 · The paper itself

Abstract

Stemmed from our novel single-photon imaging concept of detector self-collimation-which leverages detectors themselves as collimators to overcome the inherent resolution-sensitivity trade-off in conventional SPECT-this study presents the design and evaluation of the first full-ring self-collimation SPECT (SC-SPECT) scanner for small animal imaging. The system features four concentric detector rings and two interchangeable high-aperture-ratio tungsten collimator rings optimized for high-resolution (HR) and general-purpose (GP) imaging applications. Detector rings contain 480, 720, 960, and 1,200 evenly distributed GAGG(Ce) scintillators, each measuring 0.84 mm (tangential) $\times 6$ mm (radial) $\times 20$ mm (axial) and separated by 0.84-mm gaps to enable effective photon collimation. Inner detector rings and the collimator ring collectively provide collimation for photons reaching subsequent outer rings. Dual-end SiPM readouts facilitate axial depth-of-interaction measurements. Phantom and mouse studies are performed to assess the system's resolution, sensitivity, and field-of-view volume, and SC-SPECT demonstrates generally superior performance compared with state-of-the-art small-animal SPECT systems. Mouse bone images using

Indexed as

Image Processing, Computer-AssistedTomography, Emission-Computed, Single-PhotonAnimalsEquipment DesignMicePhantoms, Imaging

Identifiers

PMID41543952
PMCPMC12833742

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.