Evidence map›Paper›PMID 41541720›Full record

ArticleHeart rhythm O22025

Safety of bioelectrical impedance analysis in patients with cardiac implantable electronic devices: A systematic review.

Leonardo J Uribe-Cavero, Fabian A Chavez-Ecos, Kiara Camacho-Caballero, José Carlos Grados-Pintos, Patricia Vera-Maccha, Anthony Siguas-Huasasquiche, Dinesh Sharma, Carlos J Toro-Huamanchumo

Abstract read
In one paragraph

Article in Heart rhythm O2, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Leonardo J Uribe-CaveroOBEMET Center for Obesity and Metabolic Health, Lima, Peru.
Fabian A Chavez-EcosOBEMET Center for Obesity and Metabolic Health, Lima, Peru.
Kiara Camacho-CaballeroCHANGE Research Working Group, Carrera de Medicina Humana, Facultad de Ciencias de la Salud, Universidad Científica del Sur, Lima, Peru.
José Carlos Grados-PintosRed de Cardiología y Salud Pública (RCSP), Ica, Peru.
Patricia Vera-MacchaRed de Cardiología y Salud Pública (RCSP), Ica, Peru.
Anthony Siguas-HuasasquicheSociedad Científica de Estudiantes de Medicina de Ica (SOCEMI), Facultad de Medicina Humana, Universidad Nacional San Luis Gonzaga, Ica, Peru.
Dinesh SharmaNCH Rooney Heart Institute, Naples, Florida.
Carlos J Toro-HuamanchumoOBEMET Center for Obesity and Metabolic Health, Lima, Peru.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Bioelectrical impedance analysis (BIA) is widely used to assess body composition. However, its safety in patients with cardiac implantable electronic devices (CIEDs) remains uncertain owing to potential electromagnetic interference (EMI). Objective: This study aimed to evaluate potential complications associated with clinical-grade BIA use in patients with CIEDs, based on currently available evidence. Methods: We conducted a systematic review of studies published up to December 26, 2024, identified through PubMed, Embase, Scopus, and the Cochrane Library. The primary outcome was the occurrence of adverse events, including EMI, device malfunction, or arrhythmias. Results: Of 3668 records, 6 cohort studies (n = 531 patients) met the inclusion criteria. These included patients with pacemakers (n = 175), implantable cardioverter-defibrillators (n = 268), and cardiac resynchronization therapy defibrillators (n = 154). BIA protocols varied in frequency (5-500 kHz) and current intensity (typically ≤0.8 mA). No study reported clinically significant EMI, device malfunctions, or BIA-induced arrhythmias. Device parameters (eg, lead impedance, pacing thresholds) remained stable before and after BIA exposure. Risk of bias was rated as good in 1 study and fair in 5. Conclusion: Current evidence suggests that clinical-grade BIA is safe in patients with CIEDs, with no reported adverse effects or device interferences. These findings contribute to informing and potentially updating previous recommendations that discouraged BIA in this population. However, further high-quality studies are needed to confirm safety across different BIA protocols and device types. Importantly, these findings apply to clinical-grade BIA and should not be extrapolated to consumer-grade wearables, which may present a theoretical risk of CIED interference.

Indexed as

Bioelectrical impedance analysisCardiac implantable electronic devicesDefibrillatorElectromagnetic interferenceHeart failurePacemakers

Identifiers

PMID41541720
PMCPMC12800823

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.