Evidence map›Paper›PMID 41536897›Full record

ArticleImaging science in dentistry2025

Effects of exposure time and voxel size on measured alveolar bone thickness in cone-beam computed tomography: An

Graham Garvey, Werner Harumiti Shintaku, Wanda I Claro, Anastasios Karydis, Chenhao Zhao, Ayman Al Dayeh

Abstract read
In one paragraph

Article in Imaging science in dentistry, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Graham GarveyDepartment of Orthodontics, College of Dentistry, The University of Tennessee Health Science Center, Memphis, TN, USA.ORCID https://orcid.org/0009-0006-3584-5240
Werner Harumiti ShintakuDepartment of Diagnostic Sciences, College of Dentistry, The University of Tennessee Health Science Center, Memphis, TN, USA.ORCID https://orcid.org/0000-0003-2558-878X
Wanda I ClaroDepartment of Orthodontics, College of Dentistry, The University of Tennessee Health Science Center, Memphis, TN, USA.ORCID https://orcid.org/0000-0003-1260-1471
Anastasios KarydisDepartment of Periodontics, College of Dentistry, The University of Tennessee Health Science Center, Memphis, TN, USA.ORCID https://orcid.org/0000-0001-6979-1590
Chenhao ZhaoDepartment of Preventive Medicine, College of Medicine, The University of Tennessee Health Science Center, Memphis, TN, USA.ORCID https://orcid.org/0000-0001-5607-7443
Ayman Al DayehDepartment of Orthodontics, College of Dentistry, The University of Tennessee Health Science Center, Memphis, TN, USA.ORCID https://orcid.org/0000-0002-3114-7043

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: This study assessed the effects of cone-beam computed tomography (CBCT) voxel size and exposure settings on the accuracy of alveolar bone thickness (BT) measurements. Materials and Methods: Seven pig mandibles were scanned using 6 CBCT settings: 200, 400, and 600 µm voxels, each with an ultra-low dose (ULD) and a standard dose (SD) setting. BT was measured at 3 locations on 1 anterior and 1 posterior tooth. These teeth were then scanned using micro-computed tomography (micro-CT), and BT was measured at the same locations. The intraclass correlation coefficient (ICC) and paired Results: The lowest discrepancy between micro-CT and CBCT was observed with the 600 µm ULD (0.29±0.39 mm), followed by the 200 µm SD (0.41±0.72 mm). When BT was less than 2 mm, the lowest discrepancy occurred with the 200 µm SD (0.29±0.33 mm), followed by the 600 µm ULD (0.32±0.25 mm). The ICC between CBCT and micro-CT decreased as BT decreased. RMANOVA indicated no significant effect of CBCT settings on measurement accuracy. Conclusion: BT measured with the 600 µm ULD was comparable to that obtained with the 200 µm SD. The discrepancy between CBCT and micro-CT was notable, especially when BT was less than 2 mm.

Indexed as

Alveolar ProcessCone-Beam Computed TomographyObserver VariationX-Ray Microtomography

Identifiers

PMID41536897
PMCPMC12798368

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.