Evidence map›Paper›PMID 41536759›Full record

ArticleThe journal of advanced prosthodontics2025

Influence of misfit direction and abutment type on torque loss and fracture strength of implant-supported fixed dental prostheses.

Vygandas Rutkūnas, Maisa Haiek, Daniel Kules, Liudas Auškalnis, Ieva Gendviliene, Ingrida Mischitz, Tan Fırat Eyüboğlu, Mutlu Özcan

Abstract read
In one paragraph

Article in The journal of advanced prosthodontics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Vygandas RutkūnasDepartment of Prosthodontics, Institute of Odontology, Faculty of Medicine, Vilnius University, Vilnius, Lithuania.ORCID https://orcid.org/0000-0001-5740-4573
Maisa HaiekHadassah School of Dental Medicine, Hebrew University of Jerusalem, Jerusalem, Israel.ORCID https://orcid.org/0009-0008-9970-4222
Daniel KulesDepartment of Periodontology, Institute of Odontology, Faculty of Medicine, Vilnius University, Vilnius, Lithuania.ORCID https://orcid.org/0000-0002-2897-3213
Liudas AuškalnisDepartment of Prosthodontics, Institute of Odontology, Faculty of Medicine, Vilnius University, Vilnius, Lithuania.ORCID https://orcid.org/0000-0001-6113-3753
Ieva GendvilieneDepartment of Oral Surgery, Institute of Odontology, Faculty of Medicine, Vilnius University, Vilnius, Lithuania.ORCID https://orcid.org/0000-0002-1777-9781
Ingrida MischitzDepartment of Dental Medicine and Oral Health, Medical University of Graz, Graz, Austria.ORCID https://orcid.org/0000-0002-3628-2922
Tan Fırat EyüboğluDepartment of Endodontics, Faculty of Dentistry, Istanbul Medipol University, Istanbul, Türkiye.ORCID https://orcid.org/0000-0002-0308-9579
Mutlu ÖzcanClinic of Masticatory Disorders and Dental Biomaterials, Center for Dental Medicine, University of Zurich, Zurich, Switzerland.ORCID https://orcid.org/0000-0002-9623-6098

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study aimed to evaluate the effects of fatigue and misfit on the reverse torque, load-bearing capacity, and failure modes of cemented and screw-retained two-implant-supported fixed dental prostheses (FDPs). MATERIALS AND

methodsEighty CAD-CAM zirconia frameworks with porcelain veneering were assigned to three groups based on engaging (E) and non-engaging (N) abutment configurations: N-N, N-E, and E-E. Misfit scenarios included a control cast and 100 µm horizontal or vertical misfits. Frameworks were mounted on implants as screw-retained or cement-retained 3-unit FDPs, forming seven test groups and one control group (n = 10). Reverse torque was measured before and after thermomechanical cycling, followed by maximum failure load (Fmax) testing and failure mode analysis. Fmax was evaluated using two-way ANOVA, and reverse torque using mixed-effects ANOVA accounting for engagement, misfit, and implant position (α = 0.05).

resultsNo significant differences in Fmax were observed across zirconia specimen groups or engagement configurations under various misfit conditions (

conclusionThe engagement configuration of implants did not significantly affect reverse torque, fracture strength, or failure modes of cemented and screw-retained restorations, although horizontal misfit reduced load-bearing capacity.

Indexed as

CAD-CAMDental implantsDental materialsImplant-supported dental prosthesisProsthodontics

Identifiers

PMID41536759
PMCPMC12798370

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.