Evidence map›Paper›PMID 41535796›Full record

ArticleBMC oral health2026

Finite element study on the effect of bruxism on the fracture resistance of maxillary zirconia fixed partial dentures with varying anterior inter-implant distances.

Omir Aldowah, Mohammed Zarbah, Abdulrahman Aseri, Ahmed Almeshari, Mohamed I El-Anwar, Abdel Naser M Emam, Hussain Alharthi

Abstract read
In one paragraph

Article in BMC oral health, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Omir AldowahDepartment of Prosthetic Dental Science, Faculty of Dentistry, Najran University, Najran, Saudi Arabia.
Mohammed ZarbahDepartment of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha, Saudi Arabia.
Abdulrahman AseriDepartment of Preventive Dental Science, Faculty of Dentistry, Najran University, Najran, 10010, Saudi Arabia. aaaseri@nu.edu.sa.
Ahmed AlmeshariDepartment of Maxillofacial Surgery, Faculty of Dentistry, Najran University, Najran, Saudi Arabia.
Mohamed I El-AnwarMechanical Engineering Department, National Research Centre, Cario, Egypt.
Abdel Naser M EmamDepartment of Prosthetic Dental Science, Faculty of Dentistry, Najran University, Najran, Saudi Arabia.
Hussain AlharthiDental student, Faculty of Dentistry, Najran University, Najran, Saudi Arabia.

Funding

Najran University NU/EFP/MRC/13/255
6 · The paper itself

Abstract

objectiveThis study aims to investigate the effect of bruxism on the fracture resistance of maxillary zirconia fixed denture prostheses (FDP) with different inter-implant distances and different occlusion types.

methodsWe developed four finite element models that reflect maxillary fixed dental prostheses in patients with bruxism. The original version retains the prosthesis using six implants positioned at the canines, premolars, and first molars. The second one features implants positioned at the lateral incisors, canines, and second premolars. The development of two supplementary models, 3 and 4, included a reduction of the cusp height by 0.35 mm. Angle's classification, encompassing classes I, II, and III, directs the application of pressures to all models subjected to parafunctional habits, including bruxism.

resultsModel 1 exhibited the lowest values for FDP and bone deformation, measuring 77 μm and 27 μm, respectively. Model 3 followed with values ranging from 71 to 73 μm for FDP and 25 to 26 μm for bone deformation. In contrast, Models 2 and 4 demonstrated higher values, with Model 2 showing particularly elevated measurements of 104 μm for FDP and 43 μm for bone deformation. In Models 2 and 3, the Von Mises stress in the FDP was less than 500 MPa, suggesting a less risk of fatigue, whereas Models 1 and 4 surpassed this threshold. Models 1 and 3 exhibited physiological bone stress, whereas Models 2 and 4 demonstrated unsafe levels indicative of potential structural damage. Class I and II occlusions exhibited stable, low-stress profiles, while Class III occlusions resulted in increased shear and torque due to anterior occlusal displacement. This underscores the importance of occlusion-specific prosthetic design to mitigate peri-implant stress.

conclusionsThe distribution of implants in Models 1 and 3 may enhance stability and extend longevity. A 350-micron reduction in occlusal surface height was associated with reduced stress and deformation in the models, which may enhance the lifespan of the FDPs. Therefore, reducing the occlusal surface height of FDP is recommended for patients with bruxism. CLINICAL SIGNIFICANCE: It is recommended that clinicians construct maxillary zirconia FDPs with a broader implant distribution and a cusp inclination of (≤ 15º) for better outcomes in patients with bruxism. This configuration enhances prosthetic stability and reduces stress, thereby increasing longevity. Clinical protocols may encompass strategic implant placement, reduction of cusp height, and individualized occlusal design.

Indexed as

BruxismDental ImplantsDental MaterialsDental Prosthesis, Implant-SupportedDental Restoration FailureDenture, Partial, FixedFinite Element AnalysisZirconiumDental Stress AnalysisDenture DesignHumansMaxillaStress, MechanicalDental ImplantsDental MaterialsZirconiumzirconium oxideBruxismFinite element analysisImplantOcclusal surfaceTitanium

Identifiers

PMID41535796
PMCPMC12888704

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.