Influence of scan mode, tilt, and radiation dose on CT radiomic metrics.

Neha Yadav, Xiaomeng Lei, Steven Y Cen, Joshua Levy, Kristin Jensen, Bino A Varghese

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Influence of scan mode, tilt, and radiation dose on CT radiomic metrics.Journal of applied clinical medical physics · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Neha YadavKeck School of Medicine, University of Southern California, Los Angeles, California, USA.
Xiaomeng LeiKeck School of Medicine, University of Southern California, Los Angeles, California, USA.
Steven Y CenKeck School of Medicine, University of Southern California, Los Angeles, California, USA.
Joshua LevyThe Phantom Laboratory, Greenwich, New York, USA.
Kristin JensenDepartment of Physics and Computational Radiology, Oslo University Hospital, Oslo, Norway.
Bino A VargheseKeck School of Medicine, University of Southern California, Los Angeles, California, USA.ORCID https://orcid.org/0000-0002-0508-2899

Funding

University of Southern California Dean's Pilot Grant, 2020-2021
6 · The paper itself

Abstract

backgroundRadiomic features derived from computed tomography (CT) are highly susceptible to variations in acquisition parameters, which can introduce confounding effects in multicenter research and reduce diagnostic accuracy. While the effects of parameters such as scanning mode and dose have been studied, the impact of gantry tilt-despite its routine clinical use-remains underexplored in radiomics literature. PURPOSE: To systematically evaluate how scan mode (axial vs. helical), gantry tilt (0° vs. 5°), and radiation dose affect CT-based radiomic metrics using an anthropomorphic liver phantom containing six 3D-printed texture inserts, with special emphasis on the novel inclusion of tilt.

methodsTwelve unique image acquisition configurations were scanned on a GE Revolution Apex CT scanner, with each configuration repeated once. Manual segmentation of volumes of interest (VOIs) was performed, and 93 radiomic features spanning six texture families were extracted using PyRadiomics. First-order dispersion metrics (standard deviation, interquartile range, and coefficient of variation) were analyzed alongside higher-order features via regression with heatmap visualization, and repeatable, robust, and calibratable features were identified.

resultsHelical scans without tilt generally exhibited lower first-order dispersion than axial scans. Introducing a 5° tilt reduced dispersion in axial scans but had inconsistent effects in helical scans, with no coherent trend observed. Radiation dose demonstrated an expected inverse relationship with dispersion metrics. Intraclass correlation coefficient (ICC) analysis revealed that 34% of radiomic metrics exhibited good or excellent repeatability across all trials (ICC ≥ 0.6), but only 13% demonstrated good or excellent robustness, highlighting the sensitivity of radiomic metrics to scanning conditions. Regression analysis yielded 31 metrics (33%) that can be calibrated using their significant linear relationships with the parameters varied in this study, thereby allowing researchers to correct for variations in acquisition settings.

conclusionsThese findings underscore the importance of accounting for acquisition variability-including less frequently examined parameters such as tilt-when designing radiomic studies, selecting robust features, and interpreting results in clinical and multicenter studies. This approach helps distinguish meaningful biological variation from imaging artifacts, thereby improving the reliability of radiomic analysis in personalized medicine.

Indexed as

Image Processing, Computer-AssistedPhantoms, ImagingRadiomicsRadiotherapy Planning, Computer-AssistedTomography, X-Ray ComputedHumansRadiation DosageRadiotherapy, Intensity-Modulatedimage acquisitionphantom studyquality controlradiomic analysis

Identifiers

PMID41532307
PMCPMC12800920

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.