Evidence map›Paper›PMID 41531927›Full record

ArticleAnnals of vascular diseases2026

Comparative Analysis of Adhesive Strength and Flexibility in Surgical Sealants for Cardiovascular Surgery.

Akiyoshi Yamamoto, Shinichiro Shimura, Kenji Kuwaki, Hidekazu Furuya, Sohsyu Kotani, Kimiaki Okada, Keisuke Ozawa, Goro Kishinami, Shigeyuki Ozaki, Yasunori Cho

Abstract read
In one paragraph

Article in Annals of vascular diseases, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Akiyoshi YamamotoDepartment of Cardiovascular Surgery, Tokai University School of Medicine, Isehara, Kanagawa, Japan.
Shinichiro ShimuraDepartment of Cardiovascular Surgery, Toho University Ohashi Medical Center, Tokyo, Japan.
Kenji KuwakiDepartment of Cardiovascular Surgery, Tokai University School of Medicine, Isehara, Kanagawa, Japan.
Hidekazu FuruyaDepartment of Cardiovascular Surgery, Tokai University Hachioji Hospital, Hachioji, Tokyo, Japan.
Sohsyu KotaniDepartment of Cardiovascular Surgery, Tokai University School of Medicine, Isehara, Kanagawa, Japan.
Kimiaki OkadaDepartment of Cardiovascular Surgery, Tokai University School of Medicine, Isehara, Kanagawa, Japan.
Keisuke OzawaDepartment of Cardiovascular Surgery, Tokai University School of Medicine, Isehara, Kanagawa, Japan.
Goro KishinamiDepartment of Cardiovascular Surgery, Tokai University School of Medicine, Isehara, Kanagawa, Japan.
Shigeyuki OzakiDepartment of Cardiovascular Surgery, Toho University Ohashi Medical Center, Tokyo, Japan.
Yasunori ChoDepartment of Cardiovascular Surgery, Tokai University School of Medicine, Isehara, Kanagawa, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objectives: The objective of this study was to compare the adhesive strength and flexibility of 3 surgical sealants-synthetic (Hydrofit; Sanyo Chemical Industries, Kyoto, Japan), albumin-based (BioGlue; Artivion, Kennesaw, GA, USA), and fibrin-based (Beriplast; CSL Behring, Tokyo, Japan)-which are commonly used in cardiovascular surgery but unexplored under identical experimental conditions. Methods: Adhesive strength was evaluated using a tensile adhesion test on collagen, polyester, and polytetrafluoroethylene substrates. Flexibility was assessed by measuring the maximum stress and elongation at failure in Hydrofit and BioGlue film samples. Beriplast was excluded as it failed to form films. Results: Hydrofit and BioGlue showed similar collagen-collagen adhesion strengths (p = 0.11), while Beriplast was significantly weaker (p <0.01). Hydrofit outperformed both BioGlue and Beriplast (p <0.01) in collagen-polyester and collagen-expanded polytetrafluoroethylene (ePTFE) adhesions. Hydrofit also demonstrated a significantly higher elongation rate, strength, and maximum stress before rupture than BioGlue. Conclusions: These surgical sealants possess distinct adhesive and mechanical characteristics. Hydrofit showed stable adhesion across various substrates, with notable flexibility. BioGlue displayed adequate adhesion on collagen surfaces but had restricted flexibility. Beriplast demonstrated reduced adhesion. Although only adhesive strength and flexibility were evaluated, such properties may offer valuable insights into sealant traits contextually. These potentially aid in the selection of appropriate sealants for cardiovascular procedures that require both durable adhesion and tissue compliance. Further

Indexed as

adhesive strength testBeriplastBioGlueflexibility testHydrofit

Identifiers

PMID41531927
PMCPMC12795642

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.