Evidence map›Paper›PMID 41528485›Full record

ArticleEuropean journal of trauma and emergency surgery : official publication of the European Trauma Society2026

Novel 3D-navigated screw corridors for posterior pelvic ring stabilization: a finite element analysis.

Eftychios Bolierakis, Maximilian Praster, Hatem Alabdulrahman, Ulf Krister Hofmann, Christian Herren, Roman Michalik, Michel Teuben, Hans-Christoph Pape, Frank Hildebrand, Till Berk

Abstract read
In one paragraph

Article in European journal of trauma and emergency surgery : official publication of the European Trauma Society, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Eftychios Bolierakis *Department of Orthopaedics, Trauma and Reconstructive Surgery, Medical Faculty, RWTH Aachen University, Pauwelsstraße 30, 52074, Aachen, Germany. ebolierakis@ukaachen.de.ORCID http://orcid.org/0009-0005-9542-8900
Maximilian Praster *Department of Orthopaedics, Trauma and Reconstructive Surgery, Medical Faculty, RWTH Aachen University, Pauwelsstraße 30, 52074, Aachen, Germany.
Hatem AlabdulrahmanDepartment of Orthopaedics, Trauma and Reconstructive Surgery, Medical Faculty, RWTH Aachen University, Pauwelsstraße 30, 52074, Aachen, Germany.
Ulf Krister HofmannDepartment of Orthopaedics, Trauma and Reconstructive Surgery, Medical Faculty, RWTH Aachen University, Pauwelsstraße 30, 52074, Aachen, Germany.
Christian HerrenDepartment of Orthopaedics, Trauma and Reconstructive Surgery, Medical Faculty, RWTH Aachen University, Pauwelsstraße 30, 52074, Aachen, Germany.
Roman MichalikDepartment of Orthopaedics, Trauma and Reconstructive Surgery, Medical Faculty, RWTH Aachen University, Pauwelsstraße 30, 52074, Aachen, Germany.
Michel TeubenDepartment of Trauma, University Hospital Zurich, Raemistrasse 100, Zurich, 8091, Switzerland.
Hans-Christoph PapeDepartment of Trauma, University Hospital Zurich, Raemistrasse 100, Zurich, 8091, Switzerland.
Frank HildebrandDepartment of Orthopaedics, Trauma and Reconstructive Surgery, Medical Faculty, RWTH Aachen University, Pauwelsstraße 30, 52074, Aachen, Germany.
Till BerkDepartment of Orthopaedics, Trauma and Reconstructive Surgery, Medical Faculty, RWTH Aachen University, Pauwelsstraße 30, 52074, Aachen, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposePosterior pelvic ring stabilization is technically demanding due to the complex local anatomy and limited osseous corridors. Advances in 3D navigation may allow for new screw trajectories previously infeasible with conventional fluoroscopy.

methodsA finite element model (FE) of a pelvis (Synbone LSS4060/Hard

resultsConventional transsacral screws (Variants I-II) demonstrated the most uniform stress distribution and lowest peak stresses (7.17 MPa). Among novel configurations, Variant III achieved favorable compressive load transfer and lower shear stresses. Variant IV exhibited the highest overall stress (17.80 MPa), while Variant V demonstrated intermediate behavior.

conclusionThe proposed 3D-navigated oblique screw pathways are anatomically feasible and may offer biomechanical advantages under certain conditions. These findings support further validation using cadaveric and clinical studies.

Indexed as

Bone ScrewsFinite Element AnalysisFracture Fixation, InternalFractures, BoneImaging, Three-DimensionalPelvic BonesSurgery, Computer-AssistedBiomechanical PhenomenaHumansStress, Mechanical3 d navigationFinite element modelNovel sacrum osteosynthesisOrthopedicsPosterior pelvic ring disruptionScrew corridors

Identifiers

PMID41528485
PMCPMC12799661

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.