Evidence map›Paper›PMID 41527100›Full record

ArticleJournal of orthopaedic surgery and research2026

The design and biomechanical study of the 3D-printed implanted cervical vertebral cage.

Ruoheng Yin, Weiyu Jiang, Junhui Chu, Yunlin Chen, Xudong Hu, Weihu Ma

Abstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. [Effectiveness analysis of anterior intervertebral osteotomy and fusion assisted by inflection point of uncinate process for treatment of cervical spondylotic myelopathy].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Ruoheng YinNingbo No.6 Hospital, Ningbo, Zhejiang, China.
Weiyu JiangNingbo No.6 Hospital, Ningbo, Zhejiang, China. weiyujiang1210@163.com.
Junhui ChuNingbo No.6 Hospital, Ningbo, Zhejiang, China.
Yunlin ChenNingbo No.6 Hospital, Ningbo, Zhejiang, China.
Xudong HuNingbo No.6 Hospital, Ningbo, Zhejiang, China.
Weihu MaNingbo No.6 Hospital, Ningbo, Zhejiang, China.

Funding

Funded by Ningbo Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation 2024L004Medical and Health Science and Technology Project of Zhejiang Province 2024KY381
6 · The paper itself

Abstract

backgroundAn in vitro biomechanical study was conducted to assess the immediate postoperative stability and compressive stiffness of monosegment slot-expansion decompression with implantation of a novel 3D-printed implanted cervical vertebral cage. A comparative analysis was performed against traditional anterior cervical discectomy and fusion (ACDF) constructs and partial vertebrectomy with cage implantation. The objective was to provide biomechanical validation for the rationale and efficacy of the 3D-printed implanted cervical vertebral cage in clinical use.

methodsFifteen fresh goat cervical spine specimens were divided into five groups: (1) intact control, (2) discectomy-only, (3) traditional ACDF cage, (4)partial corpectomy with traditional cage, (5) slot-expansion decompression with 3D-printed implanted cervical vertebral cage. Range of motion (ROM) was measured under 2.0 N·m loading in flexion, extension, lateral bending, and axial rotation. Axial compressive stiffness was assessed under vertical loads (50 N, 100 N, 150 N, 200 N).

resultsThe 3D-printed implanted cervical vertebral cage group exhibited slightly lower flexion ROM than traditional ACDF and vertebral endplate resection group, though statistically insignificant (P > 0.05). Extension ROM was marginally reduced compared to intact and ACDF groups, though statistically insignificant (P > 0.05), similar to the partial corpectomy group (P > 0.05). Lateral bending ROM and rotation ROM showed no intergroup differences (P > 0.05). All surgical groups demonstrated higher compressive stiffness than the intact spine (P < 0.05). Under physiological loads (around 50 N), the 3D-printed implanted cervical vertebral fusion cage's stiffness matched traditional ACDF (P > 0.05); at higher loads (> 100 N), it was lower than ACDF (P < 0.05) but remained superior tovertebral partial corpectomy group (P < 0.05).

conclusionThis study demonstrates that the 3D-printed implanted cervical vertebral cage, used with monosegmental slot-expansion decompression, provides a biomechanical stability profile comparable to traditional ACDF, while offering greater subsidence resistance than partial corpectomy. These biomechanical findings suggest that the novel 3D-printed cage design may serve as a stable alternative for slot-expansion decompression. Further in vivo and clinical studies are warranted to confirm its long-term performance.

Indexed as

Cervical VertebraeDecompression, SurgicalPrinting, Three-DimensionalProsthesis DesignSpinal FusionAnimalsBiomechanical PhenomenaDiskectomyGoatsRange of Motion, ArticularBiomechanical testCervical cageCervical spineGoatInitial stability

Identifiers

PMID41527100
PMCPMC12888577

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.