A Dual-Energy CBCT With Reduced Scatter and Cone Beam Artifacts Using an X-Ray Source Array and Interlaced Spectral Filters.

Yuanming Hu, Boyuan Li, Shuang Xu, Christina R Inscoe, Donald A Tyndall, Yueh Z Lee, Jianping Lu, Otto Zhou

Abstract read
In one paragraph

Article in IEEE transactions on bio-medical engineering, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Yuanming Hu
Boyuan Li
Shuang Xu
Christina R Inscoe
Donald A Tyndall
Yueh Z Lee
Jianping Lu
Otto Zhou

Funding

Improve the diagnostic accuracy of CBCT for oral lesionsR56DE030962 · NIDCR · UNIV OF NORTH CAROLINA CHAPEL HILL · PI ZHOU, OTTO Z · 2021 to 2021
$512k
Developing a dual energy x-ray source for low-cost spectral CTR21EB032919 · NIBIB · UNIV OF NORTH CAROLINA CHAPEL HILL · PI ZHOU, OTTO Z · 2022 to 2023
$414k
NIBIB NIH HHS R21 EB032919NIDCR NIH HHS R56 DE030962
6 · The paper itself

Abstract

objectiveTo design a dual-energy cone beam computed tomography (DE-CBCT) scanner with reduced scatter and cone beam artifacts.

methodsThe scanner designed for maxillofacial imaging comprises a carbon nanotube (CNT) X-ray source array with multiple focal spots ("sources") and an energy integrating flat panel detector (FPD). The X-ray photons from each focal spot were narrowly collimated in the axial direction and were filtered by interlaced low- and high-energy spectral filters. Two sets of projection images were acquired by sequentially activating the X-ray beams from each source in one gantry rotation. The projections were processed using a one-step inversion algorithm. An anthropomorphic head phantom, a Defrise phantom and a water-equivalent phantom containing calcium and iodine inserts were used to compare the performance of the new dual-energy multisource CBCT (DE-MS-CBCT) with a conventional DE-CBCT using the same air-kerma.

resultsThe DE-MS-CBCT eliminated the cone beam artifacts, reduced the degree of cupping artifacts from 14.53% to 2.94%, and lowered the mean relative error of water density from 15.3% to 1.7%, while the accuracies for iodine and calcium densities were comparable. The contrast-noise-ratios (CNR) of the calcium and iodine inserts against the solid water increased by 4.8% -53.4%.

conclusionThe DE-MS-CBCT reduces scatter and cone-beam artifacts, increases the image CNR, and enhances accuracy of materials quantification without increasing X-ray exposure compared to the conventional DE-CBCT. SIGNIFICANCE: The results demonstrate a new DE-CBCT method with improved image quality and accuracy of materials quantification without the need for an energy sensitive detector or kV switching.

Indexed as

Cone-Beam Computed TomographyAlgorithmsArtifactsEquipment DesignHumansPhantoms, ImagingScattering, Radiation