A Dual-Energy CBCT With Reduced Scatter and Cone Beam Artifacts Using an X-Ray Source Array and Interlaced Spectral Filters.
Article in IEEE transactions on bio-medical engineering, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
objectiveTo design a dual-energy cone beam computed tomography (DE-CBCT) scanner with reduced scatter and cone beam artifacts.
methodsThe scanner designed for maxillofacial imaging comprises a carbon nanotube (CNT) X-ray source array with multiple focal spots ("sources") and an energy integrating flat panel detector (FPD). The X-ray photons from each focal spot were narrowly collimated in the axial direction and were filtered by interlaced low- and high-energy spectral filters. Two sets of projection images were acquired by sequentially activating the X-ray beams from each source in one gantry rotation. The projections were processed using a one-step inversion algorithm. An anthropomorphic head phantom, a Defrise phantom and a water-equivalent phantom containing calcium and iodine inserts were used to compare the performance of the new dual-energy multisource CBCT (DE-MS-CBCT) with a conventional DE-CBCT using the same air-kerma.
resultsThe DE-MS-CBCT eliminated the cone beam artifacts, reduced the degree of cupping artifacts from 14.53% to 2.94%, and lowered the mean relative error of water density from 15.3% to 1.7%, while the accuracies for iodine and calcium densities were comparable. The contrast-noise-ratios (CNR) of the calcium and iodine inserts against the solid water increased by 4.8% -53.4%.
conclusionThe DE-MS-CBCT reduces scatter and cone-beam artifacts, increases the image CNR, and enhances accuracy of materials quantification without increasing X-ray exposure compared to the conventional DE-CBCT. SIGNIFICANCE: The results demonstrate a new DE-CBCT method with improved image quality and accuracy of materials quantification without the need for an energy sensitive detector or kV switching.