Quantitative performance of a 3D CZT and conventional SPECT/CT for Tb-161 imaging.
Article in EJNMMI physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Quantitative accuracy ofEJNMMI physics · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThis study aimed to assess the imaging performance of a 3D CZT SPECT/CT system for Tb-161 and compare its quantitative accuracy and image quality with those of a conventional [NaI(Tl)]-based SPECT/CT system.
methodsA NEMA Image Quality (IQ) phantom was scanned with a 3D CZT SPECT/CT (Veriton, Spectrum Dynamics) for 8 min per bed position and with a conventional SPECT/CT (Symbia T16, by Siemens) for 16 min per bed position. The 3D CZT SPECT acquisition time was virtually shortened by reparsing the listmode data. The NEMA IQ phantom was scanned with a cold background and with a sphere-to-background ratio (SBR) of 20:1 and 10:1, with 0.71 MBq/mL in the spheres. Clinical reconstruction protocols were chosen by maximizing the SBR (for the four largest spheres) while minimizing the background noise.
resultsThe optimal SBR-to-noise trade-off was achieved at 48 updates for the Symbia and 50 updates for the Veriton. The Veriton exhibited a 20% and 34% higher SBR with a 19% and 10% lower CoV compared to the Symbia for the 10:1 and 20:1 spheres to background ratios, respectively. The calibration factors were determined as 15.17 and 4.8 [Formula: see text] cps/MBq for the Symbia and Veriton, respectively. Reducing the scan time had minimal effect on SBR, but a twofold count reduction increased background noise by 11%.
conclusionQuantitative Tb-161 SPECT imaging can be performed using both a conventional and a 3D CZT SPECT/CT. Given its higher sensitivity, the 3D CZT system is preferred, as it achieved better image quality with an 8-min acquisition compared to a conventional system with a 16-min acquisition.