Evidence map›Paper›PMID 41522787›Full record

ArticleJournal of experimental orthopaedics2026

Effect of tibial tray backside design on stress transfer and micromotion in uncemented posterior-stabilized TKA: A finite element study.

Zhenxian Chen, Zhangwen Ma, Bo Liang, Jianian Han, Jing Zhang, Yinghu Peng, Zhongmin Jin

Abstract read
In one paragraph

Article in Journal of experimental orthopaedics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Zhenxian ChenSchool of Construction Machinery Chang' an University Xi'an Shaanxi China.
Zhangwen MaDepartment of Bone Surgery Affiliated Hospital of Yan' an University Yan'an Shaanxi China.ORCID https://orcid.org/0000-0002-3279-6504
Bo LiangSchool of Construction Machinery Chang' an University Xi'an Shaanxi China.ORCID https://orcid.org/0009-0009-6942-9087
Jianian HanSchool of Construction Machinery Chang' an University Xi'an Shaanxi China.
Jing ZhangSchool of Construction Machinery Chang' an University Xi'an Shaanxi China.
Yinghu PengCAS Key Laboratory of Human-Machine Intelligence-Synergy Systems Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences Shenzhen China.
Zhongmin JinInstitute of Medical and Biological Engineering, School of Mechanical Engineering University of Leeds Leeds UK.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: The uncemented posterior-stabilized total knee arthroplasty (PS-TKA) gained increasing acceptance as younger and active patients have higher requirements for the lifespan and functionality of prostheses, because their frequent gait and deep-flexion activities may amplify tibial implant-bone interface micromotion and increase the risk of early tibial loosening. The purpose of this study is to evaluate the biomechanical fixation effects of three different tibial tray backside designs, with the aim of informing surgeons in selecting the most appropriate fixation strategy for uncemented PS-TKA. Methods: The finite element and micromotion models were developed to quantify the tibial von Mises stress and interface micromotion under the knee loading conditions. The effects of three common tibial tray backside designs, including a cylindrical stem with a triple flat keel (CS-TFK), a tapered stem with a double flat keel (TS-DFK) and a cylindrical stem with a double serrated keel (CS-DSK), on stress transfer and interface micromotion were compared. Results: During walking, all designs exhibited similar stress and micromotion patterns, with minimal risk for prostheses instability. During squatting, the cylindrical stem with double serrated keel design exhibited the highest proximal tibial stress (124.03 MPa) and the lowest maximum micromotion (361.91 µm), resulting in the largest area suitable for bone ingrowth (42.53%). In contrast, the tapered stem with double flat keel design had the lowest stress (90.70 MPa), and its area at risk for poor osseointegration (micromotion >150 µm) increased by 44.70% compared with the cylindrical stem with double serrates keel design. Discussion: The tibial tray backside design influenced its primary fixation. Among the evaluated designs, the CS-DSK balanced stress transfer and interface micromotion, suggesting it may be favored for uncemented PS-TKA in younger, active patients to lower the likelihood of early tibial aseptic loosening. CS-DSK favored early ingrowth but produced higher local stresses, so overload risk should be monitored in older patients with osteoporosis. Level of Evidence: N/A.

Indexed as

interface micromotionposterior‐stabilized prosthesisstress transfertibial tray backside designtotal knee arthroplasty

Identifiers

PMID41522787
PMCPMC12784101

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials