Evidence map›Paper›PMID 41522136›Full record

ArticleJournal of thoracic disease2025

Feasibility and safety of argon plasma coagulation as hemostatic tool during medical thoracoscopy.

David Abia-Trujillo, Rodrigo Funes-Ferrada, Alejandra Yu Lee-Mateus, Alanna Barrios-Ruiz, Sofia Valdes-Camacho, Bryan F Vaca-Cartagena, Kelly S Robertson, Sebastian Fernandez-Bussy

Abstract read
In one paragraph

Article in Journal of thoracic disease, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

David Abia-TrujilloDivision of Pulmonary, Allergy, and Sleep Medicine, Mayo Clinic Florida, Jacksonville, FL, USA.ORCID https://orcid.org/0000-0002-2064-292X
Rodrigo Funes-FerradaDivision of Pulmonary, Allergy, and Sleep Medicine, Mayo Clinic Florida, Jacksonville, FL, USA.ORCID https://orcid.org/0009-0007-3361-5107
Alejandra Yu Lee-MateusDivision of Pulmonary, Allergy, and Sleep Medicine, Mayo Clinic Florida, Jacksonville, FL, USA.ORCID https://orcid.org/0000-0003-1384-6761
Alanna Barrios-RuizDivision of Pulmonary, Allergy, and Sleep Medicine, Mayo Clinic Florida, Jacksonville, FL, USA.ORCID https://orcid.org/0000-0001-8332-8682
Sofia Valdes-CamachoDivision of Pulmonary, Allergy, and Sleep Medicine, Mayo Clinic Florida, Jacksonville, FL, USA.ORCID https://orcid.org/0009-0008-3013-3919
Bryan F Vaca-CartagenaDivision of Pulmonary, Allergy, and Sleep Medicine, Mayo Clinic Florida, Jacksonville, FL, USA.ORCID https://orcid.org/0000-0003-3970-3259
Kelly S RobertsonDivision of Pulmonary, Allergy, and Sleep Medicine, Mayo Clinic Florida, Jacksonville, FL, USA.
Sebastian Fernandez-BussyDivision of Pulmonary, Allergy, and Sleep Medicine, Mayo Clinic Florida, Jacksonville, FL, USA.ORCID https://orcid.org/0000-0002-3847-4127

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Medical thoracoscopy (MT) is a minimally invasive procedure used for diagnosing and managing undiagnosed pleural effusions. Argon plasma coagulation (APC) is a non-contact electrosurgical technique widely used in gastrointestinal and bronchoscopic procedures, yet its application in MT remains underreported. This study describes the APC technique during MT for hemostasis and evaluates its safety and feasibility. Methods: We conducted a retrospective observational study of patients who underwent MT with APC at Mayo Clinic, Jacksonville, FL, between December 1, 2022 and April 4, 2024. Patient demographics, procedural details, and pleural fluid analysis were recorded. Hemostasis was achieved using a rigid APC applicator, with bleeding severity assessed using the Validated Intraoperative Bleeding Scale (VIOPS). Descriptive statistical analyses were performed. Results: Twenty patients (median age: 72 years) underwent MT with APC, primarily for recurrent pleural effusion (95%). Adhesiolysis was performed in 60% of cases, and pleural biopsies were obtained in 95%. The median pleural fluid volume removed was 642.5 mL. A single bleeding complication (5%) was recorded (VIOPS score ≥2). No cases of air embolism were observed. Histopathology revealed malignancy in 21.1% of biopsies. Conclusions: MT with APC appears to be a safe and effective technique for achieving hemostasis following pleural biopsy, with a low complication rate. This study provides a foundation for future research on the role of APC in pleuroscopy and its potential advantages over conventional hemostatic techniques.

Indexed as

Argon plasma coagulation (APC)hemostasismedical thoracoscopy (MT)pleural biopsypleural effusion

Identifiers

PMID41522136
PMCPMC12780407

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.