Evidence map›Paper›PMID 41522071›Full record

ArticleQuantitative imaging in medicine and surgery2026

Characterization of a novel large-area electronic portal imaging device system for a ring-shaped HalosTx linear accelerator in radiotherapy quality assurance.

Guyu Dai, Dong Gao, Qing Xiao, Ying Song, Guangjun Li, Sen Bai

Abstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Guyu Dai *Department of Radiotherapy Physics & Technology, West China Hospital, Sichuan University, Chengdu, China.
Dong Gao *United Imaging Healthcare, Shanghai, China.
Qing XiaoDepartment of Radiotherapy Physics & Technology, West China Hospital, Sichuan University, Chengdu, China.
Ying SongDepartment of Radiotherapy Physics & Technology, West China Hospital, Sichuan University, Chengdu, China.
Guangjun LiDepartment of Radiotherapy Physics & Technology, West China Hospital, Sichuan University, Chengdu, China.
Sen BaiDepartment of Radiotherapy Physics & Technology, West China Hospital, Sichuan University, Chengdu, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Electronic portal imaging device (EPID)-based in vivo dosimetry (IVD) has attracted considerable interest in recent years. Nevertheless, the limited detection area of conventional EPID systems has hindered their broad clinical adoption. Therefore, this study evaluated a novel large-area EPID (65 cm × 61 cm) integrated into the HalosTx linear accelerator (linac), focusing on stability, imaging quality, field coverage, and error sensitivity for radiotherapy quality assurance (QA). Methods: Basic physical characteristics, including short-term repeatability, dose-response linearity, the influence of gantry angle on dose, and dose-rate dependencies, were first tested. Megavolt (MV) imaging quality tests were then performed to evaluate scaling, spatial resolution, uniformity, contrast, and noise. Subsequently, field coverage and sensitivity were tested across various treatment plans. Additionally, patient setup errors for a breast cancer treatment plan were simulated using a female thorax phantom to explore the sensitivity of the system to setup errors. Results: The EPID demonstrated high stability in basic physical characteristics, with maximum deviations of 0.25% for short-term repeatability, 0.6% for dose-response linearity, 0.757% for gantry angle influence, and 0.372% for dose-rate dependency. The results of scaling, spatial resolution, uniformity, contrast, and noise were 0 mm, 0.31 lp/mm, 99.39%, 0.74, and 161.33, respectively. Benefitting from the 65 cm × 61 cm detector effective area, this EPID successfully monitored all planning beam fields across various treatment plans. Conversely, the Vital Beam and Versa HD systems could only monitor 60% of the beam fields for breast cancer. The sensitivity to machine-related errors was calculated to be 0.2 mm for jaw position, 0.2 mm for multileaf collimator (MLC) position, 0.1% for linac output, 0.5° for collimator rotation. The phantom test for breast cancer highlighted the unique angle-dependent gamma analysis of this EPID system, wherein each beam was subdivided for further analysis. This approach revealed notably high sensitivity to setup errors, particularly in the angular ranges of 56.1°-140° clockwise and 140°-78° counterclockwise. Conclusions: Our preliminary findings indicate that the new EPID system exhibits good stability, favorable imaging quality, broad field coverage, and high sensitivity, suggesting its potential to facilitate novel EPID-based applications in radiotherapy.

Indexed as

Electronic portal imaging device (EPID)in vivoquality assurance (QA)transit dosimetry

Identifiers

PMID41522071
PMCPMC12780731

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.