Evidence map›Paper›PMID 41522049›Full record

ArticleQuantitative imaging in medicine and surgery2026

Performance of multi-planar volume rendering versus maximum intensity projection and minimum intensity projection on pulmonary nodule detection.

Sifan Chen, Ke Zhang, Wangjia Li, Weiwei Jing, Yundan Zhang, Renjun Luo, Fajin Lv

Abstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Sifan Chen *Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.
Ke Zhang *Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.
Wangjia LiDepartment of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.
Weiwei JingDepartment of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.
Yundan ZhangDepartment of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.
Renjun LuoDepartment of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.
Fajin LvDepartment of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Pulmonary nodule detection is critical for the early diagnosis of lung cancer. However, the increasing volume of thin-section computed tomography (CT) data challenges radiologists' accuracy and efficiency. While post-processing techniques like maximum intensity projection (MIP) and minimum intensity projection (MinIP) are used to improve detection, they have limitations in visualizing nodules of varying densities and sizes. Multiplanar volume rendering (MPVR), an advanced three-dimensional (3D) reconstruction technique, may overcome these drawbacks. This study aimed to systematically compare the diagnostic efficacy of MPVR with conventional MIP and MinIP for detecting pulmonary nodules across different densities and sizes. Methods: This retrospective study analyzed thin-section CT images from 183 patients diagnosed with pulmonary nodules between January 2023 and October 2023. MPVR, MIP, and MinIP images were independently reviewed by two radiologists, with nodule detection rates compared across density [solid nodules (SNs), part-SNs (PSNs), ground-glass nodules (GGNs)] and size categories (<5 mm, 5-10 mm, >10 mm). Statistical analysis including Wilcoxon and Bayesian Wilcoxon signed-rank tests, and interobserver agreement was assessed using kappa statistics. Results: A total of 1,018 SNs, 146 PSNs, and 583 GGNs were detected across all imaging methods. MPVR demonstrated superior detection rates, identifying 91% of SNs, 85% of PSNs, and 71% of GGNs, compared to 74%, 47%, and 58% with MIP and 51%, 48%, and 86% with MinIP, respectively. For nodules smaller than 5 mm, MPVR detected 87%, significantly higher than 69% with MIP and 60% with MinIP (P<0.05 and Bayes factor >3). MPVR showed excellent interobserver agreement (κ=0.913), which was comparable to MIP (κ=0.949) and MinIP (κ=0.972). The use of optimized threshold settings and pseudo-color visualization in MPVR facilitated improved differentiation between nodules and surrounding tissues. Conclusions: MPVR demonstrated superior performance over MIP and MinIP in detecting most types and sizes of pulmonary nodules; however, MinIP was found to be more effective for GGNs. These findings highlight MPVR's potential to improve early lung cancer diagnosis, streamline radiological workflows, and reduce diagnostic variability. Future studies integrating MPVR with artificial intelligence-based detection tools are warranted to further validate its clinical utility.

Indexed as

computed tomography (CT)maximum intensity projection (MIP)minimum intensity projection (MinIP)multiplanar volume rendering (MPVR)Pulmonary nodule

Identifiers

PMID41522049
PMCPMC12780691

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.