Evidence map›Paper›PMID 41522003›Full record

ArticleQuantitative imaging in medicine and surgery2026

Terahertz meta-biosensor for bovine serum albumin sensing based on electromagnetic-induced transparency-like effect.

Zhongquan Zhang, Mengyang Cong, Junchi Ma, Rui Zhao, Wei Song, Jianfeng Qiu

Abstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Zhongquan ZhangSchool of Radiology, Shandong First Medical University & Shandong Academy of Medical Sciences, Tai'an, China.
Mengyang CongSchool of Radiology, Shandong First Medical University & Shandong Academy of Medical Sciences, Tai'an, China.
Junchi MaSchool of Radiology, Shandong First Medical University & Shandong Academy of Medical Sciences, Tai'an, China.
Rui ZhaoSchool of Radiology, Shandong First Medical University & Shandong Academy of Medical Sciences, Tai'an, China.
Wei SongSchool of Radiology, Shandong First Medical University & Shandong Academy of Medical Sciences, Tai'an, China.
Jianfeng QiuThe First Affiliated Hospital of Shandong First Medical University, Jinan, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Bovine serum albumin (BSA) sensing plays an important role in the diagnosis of various diseases, yet, there is still a lack of a cost-effective terahertz solution. Terahertz metamaterials based on electromagnetically induced transparency (EIT)-like effects show significant potential for biosensing due to their narrow transparent peak. This study aims to fabricate terahertz metamaterials based on EIT effect for non-destructive, trace-level detection of BSA. Methods: We demonstrate a multiband EIT-like metasurface that merges C-, toroidal, and D-shaped resonators to generate two transparency windows at 0.973 and 1.118 THz via strong bright-bright near-field coupling between adjacent resonators. Finite-element modelling was used to optimise the bright-bright near-field coupling before fabricating the 200-nm-contact-lithography device on a quartz substrate. A 100 µL aliquot of 0 to 6 mg/mL BSA solution was pipetted onto the metasurface. After drying at 50 ℃ for 20 min in an oven, the sample was measured with a terahertz time-domain spectrometer. The resonance shift was used to determine the sensitivity of the fabricated terahertz metamaterial for BSA detection and to calculate the limit of detection. Results: Simulated frequency sensitivity reached 222.6 GHz/RIU (refractive index unit) and 257.8 GHz/RIU at 0.973 and 1.118 THz, respectively. For BSA in water, the lower-frequency peak gave an experimental sensitivity of 14.43 GHz/(mg/mL) and 18.98 GHz/(mg/mL). The limit of detection was as low as 26.33 µg/mL and 20.02 µg/mL for the two transparency peaks, respectively. Conclusions: The chip-scale sensor merges foundry-compatible fabrication, dual-band operation and sub-picogram BSA resolution, offering an immediate upgrade path for point-of-care albumin assays and bioreactor monitoring.

Indexed as

biosensingbovine serum albumin (BSA)electromagnetically induced transparency (EIT)metamaterial (MM)Terahertz

Identifiers

PMID41522003
PMCPMC12780577

What OpenQuestion holds